Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2024 Jun 19:11:1401130.
doi: 10.3389/fvets.2024.1401130. eCollection 2024.

Evaluation of sterile glove usage on digital tactile sensitivity using the Grating Orientation Task

Affiliations

Evaluation of sterile glove usage on digital tactile sensitivity using the Grating Orientation Task

Thomas O Riegel et al. Front Vet Sci. .

Abstract

Introduction: Surgical glove use may be associated with a decrease in tactile sensitivity, with thicker gloves or double-gloving techniques further altering sensation. This study evaluates digital tactile sensitivity by use of a Grating Orientation Task (GOT) with multiple sterile gloving techniques (no gloves, single standard gloving, double standard gloving, orthopedic gloves, and micro-thickness gloves).

Methods: Each participant performed the GOT at increasing grating widths until correctly noting orientation in ≥8 of 10 trials with multiple glove types or double-gloving technique. Glove order was randomly assigned and participants were blinded to the orientation and dome size.

Results: All gloves except micro-thickness gloves showed increased threshold sensitivity values (i.e. worse fingertip sensitivity) when compared to control (micro:control, p = 0.105, others:control, p < 0.05). Single-layer gloves showed no significant difference in sensitivity when compared to orthopedic (p = 0.06) or double-layer latex gloves (p = 0.26).

Discussion: Standard latex gloves decreased fingertip sensitivity when evaluated with the GOT. Double-layer and orthopedic latex gloves do not decrease sensitivity when compared with single-layer gloving. Micro-thickness gloves may provide similar tactile sensitivity to no surgical glove.

Keywords: Grating Orientation Task; double-gloving; sterile glove; surgical glove; tactile sensitivity.

PubMed Disclaimer

Conflict of interest statement

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Figures

Figure 1
Figure 1
JVP domes (Stoelting Co.), sizes ranging from 0.35 mm (top left) to 3.0 mm (bottom right) in vertical and horizontal orientations.
Figure 2
Figure 2
Threshold sensitivity values (mean ± standard error from the mean) for each gloving category evaluated. Asterisks indicate a statistically significant difference in threshold sensitivity between groups (p < 0.05).

References

    1. Wood A. AORN Guidelines for Perioperative Practice. Denver, CO: AORN; (2019). p. 881–883.
    1. Meakin LB, Gilman OP, Parsons KJ, Burton NJ, Langley-Hobbs SJ. Colored indicator undergloves increase the detection of glove perforations by surgeons during small animal orthopedic surgery: a randomized controlled trial. Vet Surg. (2016) 45:709–14. 10.1111/vsu.12519 - DOI - PMC - PubMed
    1. Laine T, Aarnio P. How often does glove perforation occur in surgery? Comparison between single gloves and a double-gloving system. Am J Surg. (2001) 181:564–6. 10.1016/S0002-9610(01)00626-2 - DOI - PubMed
    1. Pelosi A. The operating room. In:Tobias KN, Johnston S, editor Veterinary Surgery Small Animal. 2nd ed. St Louis, MO: Elsevier (2018). p. 177–192.
    1. Fry DE, Harris WE, Kohnke EN, Twomey CL. Influence of double-gloving on manual dexterity and tactile sensation of surgeons. J Am Coll Surg. (2010) 210:325–30. 10.1016/j.jamcollsurg.2009.11.001 - DOI - PubMed

LinkOut - more resources