Cardiovascular and Vector-Cardiographic Effects of Articaine Anesthesia with Epinephrine
- PMID: 38962723
- PMCID: PMC11221961
- DOI: 10.1155/2024/8610423
Cardiovascular and Vector-Cardiographic Effects of Articaine Anesthesia with Epinephrine
Abstract
The aim was to investigate the vector-cardiographic effects in patients submitted to dental extraction under local anesthesia. Twenty-one patients aged 36.6 ± 12.4 years with a clinical and radiographic indication of mandibular or maxillary tooth extraction were enrolled. The intervention was a local or mandibular nerve block anesthesia with 4% articaine hydrochloride containing epinephrine (1 : 100,000; 40 mg/ml + 10 μg/ml). Blood pressure (BP), heart rate (HR), pulse wave transit time, and vector-cardiography data were recorded throughout 3 min before and 5 min after injection. QRS- and T-wave area under the curve (QRS AUC/T AUC) were calculated from the X/Y/Z QRS-vector or T-vector. T-wave amplitude (T AM), T AUC values, and diastolic BP decreased, and HR significantly increased 4 min after injection. A transient moderate HR drop and a corresponding small increase in T AM and T AUC immediately after the injection procedure may be explained by a decreased sympathetic tone due to psychological relief. In dental anesthesia, the systemic epinephrine effects are represented by a decrease in T AUC. These effects are most pronounced in the X- and Y-leads. The 3D determination of vector planes or amplitudes is a simple method to register the sympathetic tone in local anesthesia independently of possible effects on T-wave characteristics in single leads. In conclusion, T-wave determination may help to detect even small increases in systemic adrenaline concentration in case of accidental intravascular injection. At the same time, full rhythm and spatial ischemia control is provided.
Copyright © 2024 Christoph Pökel et al.
Conflict of interest statement
The authors declare that they have no conflicts of interest.
Figures



References
-
- Lipp M., Dick W., Daubländer M., Fuder H., Stanton-Hicks M. Exogenous and endogenous plasma levels of epinephrine during dental treatment under local anesthesia. Regional Anesthesia and Pain Medicine . 1993;18(1):6–12. - PubMed
-
- Goldstein D. S., Dlonne R., Sweet J., et al. Circulatory, plasma catecholamine, cortisol, lipid, and psychological responses to a real-life stress (third molar extractions): effects of diazepam sedation and of inclusion of epinephrine with the local anesthetic. Psychosomatic Medicine . 1982;44(3):259–272. doi: 10.1097/00006842-198207000-00004. - DOI - PubMed
LinkOut - more resources
Full Text Sources