. 2024 Sep;40(9):1863-1874.
doi: 10.1007/s10554-024-03172-1. Epub 2024 Jul 4.

Predictors of appropriate therapies delivered by the implantable cardioverter-defibrillator in patients with coronary artery disease during long-term period

Affiliations

Predictors of appropriate therapies delivered by the implantable cardioverter-defibrillator in patients with coronary artery disease during long-term period

Tariel A Atabekov et al. Int J Cardiovasc Imaging. 2024 Sep.

Abstract

This prospective study aimed to investigate the ability of cardiac autonomic nervous system (CANS) activity assessment to predict appropriate implantable cardioverter-defibrillator (ICD) therapy in patients with coronary artery disease (CAD) during long-term follow-up period. We enrolled patients with CAD and ICD implantation indications that included both secondary and primary prevention of sudden cardiac death. Before ICD implantation CANS was assessed by using heart rate variability (HRV), myocardium scintigraphy with 123I-meta-iodobenzylguanidine (123I-MIBG) and erythrocyte membranes β-adrenoreactivity (EMA). The study's primary endpoint was the documentation of appropriate ICD therapy. Of 45 (100.0%) patients, 15 (33.3%) had appropriate ICD therapy during 36 months follow-up period. Patients with appropriate ICD therapy were likely to have a higher summed 123I-MIBG score delayed (p < 0.001) and lower 123I-MIBG washout rate (p = 0.008) indicators. These parameters were independently associated with endpoint in univariable and multivariable logistic regression. We created a logistic equation and calculated a cut-off value. The resulting ROC curve revealed a discriminative ability with AUC of 0.933 (95% confidence interval 0.817-0.986; sensitivity 100.00%; specificity 93.33%). Combined CANS activity assessment is useful in prediction of appropriate ICD therapy in patients with CAD during long-term follow-up period after device implantation.

Keywords: Appropriate ICD therapy; Cardiac 123I-MIBG scintigraphy; Cardiac autonomic nervous system; Implantable cardioverter-defibrillator.

PubMed Disclaimer

Similar articles

References

    1. Priori SG, Blomstrom-Lundqvist C, Mazzanti A et al (2015) 2015 ESC guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: the Task Force for the management of patients with ventricular arrhythmias and the Prevention of Sudden Cardiac Death of the European Society of Cardiology (ESC). Endorsed by: Association for European Paediatric and Congenital Cardiology (AEPC). Eur Heart J 36:2793–2867 - DOI - PubMed
    1. Zeitler EP, Al-Khatib SM, Friedman DJ et al (2017) Predicting appropriate shocks in patients with heart failure: patient level meta-analysis from SCD-HeFT and MADIT II. J Cardiovasc Electrophysiol 28:1345–1351 - DOI - PubMed - PMC
    1. Merchant FM, Quest T, Leon AR et al (2016) Implantable cardioverter-defibrillators at end of battery life: opportunities for risk (re)-stratification in ICD recipients. J Am Coll Cardiol 67:435–444 - DOI - PubMed
    1. Fukuda K, Kanazawa H, Aizawa Y et al (2015) Cardiac innervation and sudden cardiac death. Circ Res 116:2005–2019 - DOI - PubMed - PMC
    1. Shirakawa Y, Niwano S, Oikawa J et al (2020) Prediction of lethal arrhythmic events through remote monitoring using heart rate variability analysis in patients with an implantable cardioverter defibrillator. Int Heart J 61:927–935 - DOI - PubMed