Specimen volume versus yield in the BACTEC blood culture system
- PMID: 3897271
- PMCID: PMC268378
- DOI: 10.1128/jcm.22.2.292-295.1985
Specimen volume versus yield in the BACTEC blood culture system
Abstract
During a 24-month period, 5,625 blood culture specimens were collected at the Seattle Veterans Administration Medical Center in 20-ml volumes and divided into separate 10-ml aliquots. The two aliquots were processed as duplicate sets (set 1, set 2) by the BACTEC system (Johnston Laboratories, Inc., Towson, Md.). Specimens (5 ml) from each set were inoculated into aerobic (6B) and anaerobic (7C/7D) vials. A total of 434 significantly positive blood cultures were found. In 342 of these positive cultures, yielding 379 isolates (112 members of the family Enterobacteriaceae, 104 staphylococci, 87 streptococci, 27 anaerobes, 20 yeasts, 14 pseudomonads, and 15 miscellaneous organisms), there was adequate specimen volume to fill all four vials. The utilization of set 1 would have resulted only in the failure to detect 65 of 379 (17.2%) significant isolates, 52 of 342 (15.2%) positive cultures, and 20 of 198 (10.1%) bacteremic episodes. There were no significant differences in the recovery of individual species in sets 1 and 2. Although the range of isolates recovered by the aerobic and anaerobic vials of each set differed, the percent yield of total isolates was similar, indicating total isolate yield was predominantly a function of specimen volume. The addition of set 2 most dramatically increased the recovery of Escherichia coli (30%), yeasts (33%), and anaerobes (42%).
Similar articles
-
Clinical comparison of a new automated infrared blood culture system with the BACTEC 460 system.J Clin Microbiol. 1986 Feb;23(2):262-6. doi: 10.1128/jcm.23.2.262-266.1986. J Clin Microbiol. 1986. PMID: 3084548 Free PMC article.
-
Increased detection of staphylococcal bacteremia using an anti-microbial removal device.Am J Clin Pathol. 1985 Oct;84(4):509-12. doi: 10.1093/ajcp/84.4.509. Am J Clin Pathol. 1985. PMID: 3898813
-
Large-scale clinical comparison of the lysis-centrifugation and radiometric systems for blood culture.J Clin Microbiol. 1985 Dec;22(6):951-4. doi: 10.1128/jcm.22.6.951-954.1985. J Clin Microbiol. 1985. PMID: 3905850 Free PMC article.
-
Yield, clinical significance, and cost of a combination BACTEC plus Septi-Chek blood culture system.J Clin Microbiol. 1987 May;25(5):819-23. doi: 10.1128/jcm.25.5.819-823.1987. J Clin Microbiol. 1987. PMID: 3294885 Free PMC article.
-
Pediatric blood cultures.Clin Lab Med. 1994 Mar;14(1):17-30. Clin Lab Med. 1994. PMID: 8181229 Review.
Cited by
-
Time to Positive Blood Cultures Among Critically Ill Children Admitted to the PICU.Crit Care Explor. 2024 Jul 5;6(7):e1115. doi: 10.1097/CCE.0000000000001115. eCollection 2024 Jul 1. Crit Care Explor. 2024. PMID: 38968174 Free PMC article.
-
Microbial monitoring and methods of sample collection: a GITMO survey (Gruppo Trapianto di Midollo Osseo).Ecancermedicalscience. 2014 Apr 10;8:421. doi: 10.3332/ecancer.2014.421. eCollection 2014. Ecancermedicalscience. 2014. PMID: 24834116 Free PMC article.
-
Timing of specimen collection for blood cultures from febrile patients with bacteremia.J Clin Microbiol. 2008 Apr;46(4):1381-5. doi: 10.1128/JCM.02033-07. Epub 2008 Feb 27. J Clin Microbiol. 2008. PMID: 18305133 Free PMC article.
-
Optimized pathogen detection with 30- compared to 20-milliliter blood culture draws.J Clin Microbiol. 2011 Dec;49(12):4047-51. doi: 10.1128/JCM.01314-11. Epub 2011 Oct 5. J Clin Microbiol. 2011. PMID: 21976759 Free PMC article.
-
Current controversies in the detection of septicemia.Eur J Clin Microbiol. 1986 Oct;5(5):487-91. doi: 10.1007/BF02017688. Eur J Clin Microbiol. 1986. PMID: 3536496 Review. No abstract available.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical