The 45° and 60° of sagittal femoral tunnel placement in anterior cruciate ligament reconstruction provide similar knee stability
- PMID: 38973630
- DOI: 10.1002/ksa.12341
The 45° and 60° of sagittal femoral tunnel placement in anterior cruciate ligament reconstruction provide similar knee stability
Abstract
Purpose: The aim of the present study was to compare 45° and 60° of sagittal femoral tunnel angles in terms of anterior tibial translation (ATT), valgus angle and graft in situ force following anterior cruciate ligament reconstruction (ACLR).
Methods: Ten porcine knees were subjected to the following loading conditions: (1) 89 N anterior tibial load at 35° (full extension), 60° and 90° of knee flexion and (2) 5 N m valgus tibial moment at 35° and 45° of knee flexion. ATT and graft in situ force of the intact anterior cruciate ligament (ACL) and ACLR were collected using a robotic universal force/moment sensor (UFS) testing system for (1) ACL intact, (2) ACL-deficient (ACLD) and (3) two different ACLR using different sagittal femoral tunnel angles (coronal 45°/sagittal 45° and coronal 45°/sagittal 60°).
Results: During the anterior tibial load, the femoral tunnel angle of ACLR knees at coronal 45°/sagittal 45° and 60° had significantly higher ATT than that of the ACL-intact knees at 60° of knee flexion (p < 0.05). The femoral tunnel angle of ACLR knees at coronal 45°/sagittal 60° had significantly lower graft in situ force than that of the ACL-intact knees at 60° and 90° of knee flexion (p < 0.05). During the valgus tibial moment, the femoral tunnel angle of ACLR knees at coronal 45°/sagittal 45° and 60° had significantly lower graft in situ force than that of the ACL-intact knees at all knee flexions (p < 0.05).
Conclusions: The femoral tunnel angle of ACLR knees at coronal 45°/sagittal 45° provided similar ATT, valgus angle and graft in situ force to that of ACLR knees at coronal 45°/sagittal 60°. Therefore, both femoral tunnel angles could be used in ACLR, as the sagittal femoral tunnel angle does not appear to be relevant in post-operative knee stability.
Level of evidence: Not applicable.
Keywords: ACLR; ATT; in situ force; porcine knee; sagittal femoral tunnel angle.
© 2024 European Society of Sports Traumatology, Knee Surgery and Arthroscopy.
References
REFERENCES
-
- Ahsan, Z.S., Berube, E.E., Frondorf, B.J., Bin Kim, H., Marom, N., Zayyad, Z.A. et al. (2024) Role of lateral extra‐articular tenodesis in restraining internal tibial rotation: in vitro biomechanical assessment of lateral tissue engagement. The American Journal of Sports Medicine, 52(1), 87–95. Available from: https://doi.org/10.1177/03635465231211534
-
- Cheng, R., Wang, H., Jiang, Z., Dimitriou, D., Cheng, C.‐K. & Tsai, T.‐Y. (2021) The femoral tunnel drilling angle at 45° coronal and 45° sagittal provided the lowest peak stress and strain on the bone tunnels and anterior cruciate ligament graft. Frontiers in Bioengineering and Biotechnology, 9, 797389. Available from: https://doi.org/10.3389/fbioe.2021.797389
-
- Debandi, A., Maeyama, A., Hoshino, Y., Asai, S., Goto, B., Smolinski, P. et al. (2013) The effect of tunnel placement on rotational stability after ACL reconstruction: evaluation with use of triaxial accelerometry in a porcine model. Knee Surgery, Sports Traumatology, Arthroscopy, 21(3), 589–595. Available from: https://doi.org/10.1007/s00167-012-1961-2
-
- Debandi, A., Maeyama, A., Lu, S., Hume, C., Asai, S., Goto, B. et al. (2011) Biomechanical comparison of three anatomic ACL reconstructions in a porcine model. Knee Surgery, Sports Traumatology, Arthroscopy, 19(5), 728–735. Available from: https://doi.org/10.1007/s00167-010-1338-3
-
- Dhaher, Y.Y., Salehghaffari, S. & Adouni, M. (2016) Anterior laxity, graft‐tunnel interaction and surgical design variations during anterior cruciate ligament reconstruction: a probabilistic simulation of the surgery. Journal of Biomechanics, 49(13), 3009–3016. Available from: https://doi.org/10.1016/j.jbiomech.2016.07.019
MeSH terms
Grants and funding
- 31972924/National Natural Science Foundation of China
- 81972126/National Natural Science Foundation of China
- 21DZ2208200/Science and Technology Commission of Shanghai Municipality
- 22S31906000/Science and Technology Commission of Shanghai Municipality
- 23S31901000/Science and Technology Commission of Shanghai Municipality
LinkOut - more resources
Full Text Sources
Medical
Research Materials
