Automatic semantic segmentation of EHG recordings by deep learning: An approach to a screening tool for use in clinical practice
- PMID: 38996804
- DOI: 10.1016/j.cmpb.2024.108317
Automatic semantic segmentation of EHG recordings by deep learning: An approach to a screening tool for use in clinical practice
Abstract
Background and objective: Preterm delivery is an important factor in the disease burden of the newborn and infants worldwide. Electrohysterography (EHG) has become a promising technique for predicting this condition, thanks to its high degree of sensitivity. Despite the technological progress made in predicting preterm labor, its use in clinical practice is still limited, one of the main barriers being the lack of tools for automatic signal processing without expert supervision, i.e. automatic screening of motion and respiratory artifacts in EHG records. Our main objective was thus to design and validate an automatic system of segmenting and screening the physiological segments of uterine origin in EHG records for robust characterization of uterine myoelectric activity, predicting preterm labor and help to promote the transferability of the EHG technique to clinical practice.
Methods: For this, we combined 300 EHG recordings from the TPEHG DS database and 69 EHG recordings from our own database (Ci2B-La Fe) of women with singleton gestations. This dataset was used to train and evaluate U-Net, U-Net++, and U-Net 3+ for semantic segmentation of the physiological and artifacted segments of EHG signals. The model's predictions were then fine-tuned by post-processing.
Results: U-Net 3+ outperformed the other models, achieving an area under the ROC curve of 91.4 % and an average precision of 96.4 % in detecting physiological activity. Thresholds from 0.6 to 0.8 achieved precision from 93.7 % to 97.4 % and specificity from 81.7 % to 94.5 %, detecting high-quality physiological segments while maintaining a trade-off between recall and specificity. Post-processing improved the model's adaptability by fine-tuning both the physiological and corrupted segments, ensuring accurate artifact detection while maintaining physiological segment integrity in EHG signals.
Conclusions: As automatic segmentation proved to be as effective as double-blind manual segmentation in predicting preterm labor, this automatic segmentation tool fills a crucial gap in the existing preterm delivery prediction system workflow by eliminating the need for double-blind segmentation by experts and facilitates the practical clinical use of EHG. This work potentially contributes to the early detection of authentic preterm labor women and will allow clinicians to design individual patient strategies for maternal health surveillance systems and predict adverse pregnancy outcomes.
Keywords: Deep learning; Electrohysterography; Preterm delivery prediction; Semantic segmentation; Signal processing; Uterine myoelectric activity.
Copyright © 2024 The Authors. Published by Elsevier B.V. All rights reserved.
Conflict of interest statement
Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Similar articles
-
Automatic identification of motion artifacts in EHG recording for robust analysis of uterine contractions.Comput Math Methods Med. 2014;2014:470786. doi: 10.1155/2014/470786. Epub 2014 Jan 9. Comput Math Methods Med. 2014. PMID: 24523828 Free PMC article.
-
Characterization and automatic classification of preterm and term uterine records.PLoS One. 2018 Aug 28;13(8):e0202125. doi: 10.1371/journal.pone.0202125. eCollection 2018. PLoS One. 2018. PMID: 30153264 Free PMC article.
-
Automated electrohysterographic detection of uterine contractions for monitoring of pregnancy: feasibility and prospects.BMC Pregnancy Childbirth. 2018 May 8;18(1):136. doi: 10.1186/s12884-018-1778-1. BMC Pregnancy Childbirth. 2018. PMID: 29739438 Free PMC article.
-
Electrohysterography in the diagnosis of preterm birth: a review.Physiol Meas. 2018 Feb 26;39(2):02TR01. doi: 10.1088/1361-6579/aaad56. Physiol Meas. 2018. PMID: 29406317 Review.
-
Accuracy of frequency-related parameters of the electrohysterogram for predicting preterm delivery: a review of the literature.Obstet Gynecol Surv. 2009 Aug;64(8):529-41. doi: 10.1097/OGX.0b013e3181a8c6b1. Obstet Gynecol Surv. 2009. PMID: 19624864 Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous