Fatigue methods for evaluating translucent dental zirconia
- PMID: 39009334
- DOI: 10.1016/j.jdent.2024.105242
Fatigue methods for evaluating translucent dental zirconia
Abstract
Objective: To investigate fatigue methods for the evaluation of translucent zirconia and to associate in vitro failures with clinically reported ones.
Data: Studies published in English that used fatigue tests on dental translucent zirconia.
Sources: Two databases (MEDLINE/PubMed and Scopus) were electronically searched without any restriction on year of publication.
Study selection: A total of 4555 studies were identified. After removal of duplicates (78) and irrelevant articles (4316) that did not meet the inclusion criteria, 161 articles were considered eligible based on their titles and abstracts. These articles were fully read, leading to the inclusion of 41 studies in the review.
Results: The most widely used fatigue method for evaluation of translucent zirconia was step-stress (18 articles), followed by staircase (seven articles), and step-wise (two articles). Most studies had been conducted in a wet environment with the use of a stainless steel piston to apply load to cemented structures on a dentin-like substrate. Most fracture analyses indicated the fracture originated on the cementation or contact surface where the load was applied. Moreover, studies that utilized anatomical structures (dental crowns) reported fractures starting at the cervical margin of the crowns.
Conclusion: Most studies used the step-stress method. Only three studies reported failures similar to those found in clinical trials that used translucent zirconia restorations.
Clinical significance: The study findings can assist on correlating clinical failures to the ones observed in vitro.
Keywords: Dental materials; Dentistry; Fatigue; Translucent zirconia.
Copyright © 2024 Elsevier Ltd. All rights reserved.
Conflict of interest statement
Declaration of competing interest The author (ADB) is an Editorial Board Member of Journal of Dentistry and was not involved in the editorial review or the decision to publish this article.
Similar articles
-
Influence of ceramic crown design (translucent monolithic zirconia vs. bilayered) of implant-supported single crowns after mechanical cycling.J Esthet Restor Dent. 2024 Sep;36(9):1326-1336. doi: 10.1111/jerd.13237. Epub 2024 Apr 25. J Esthet Restor Dent. 2024. PMID: 38665052
-
Zirconium dioxide based dental restorations. Studies on clinical performance and fracture behaviour.Swed Dent J Suppl. 2011;(213):9-84. Swed Dent J Suppl. 2011. PMID: 21919311
-
Fracture load of ceramic restorations after fatigue loading.J Prosthet Dent. 2015 Aug;114(2):266-71. doi: 10.1016/j.prosdent.2015.03.006. Epub 2015 May 16. J Prosthet Dent. 2015. PMID: 25985741
-
A Review on Translucent Zirconia.Eur J Prosthodont Restor Dent. 2018 May 30;26(2):62-74. doi: 10.1922/EJPRD_01759Ghodsi13. Eur J Prosthodont Restor Dent. 2018. PMID: 29797847 Review.
-
Effect of cement type on the clinical performance and complications of zirconia and lithium disilicate tooth-supported crowns: A systematic review. Report of the Committee on Research in Fixed Prosthodontics of the American Academy of Fixed Prosthodontics.J Prosthet Dent. 2019 May;121(5):754-765. doi: 10.1016/j.prosdent.2018.10.011. Epub 2019 Mar 15. J Prosthet Dent. 2019. PMID: 30885580
Cited by
-
Translucent zirconia crown retention - effect of preparation, bonding and aging protocol.Clin Oral Investig. 2025 Jul 2;29(7):367. doi: 10.1007/s00784-025-06447-6. Clin Oral Investig. 2025. PMID: 40593330 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources