Response of the human choroid to short-term changes in eyelid and periocular temperature
- PMID: 39013558
- DOI: 10.1080/08164622.2024.2377391
Response of the human choroid to short-term changes in eyelid and periocular temperature
Abstract
Clinical relevance: Choroidal thickness measurement is gaining popularity in clinical practice and research as an early indicator of myopia progression. Understanding the influence of temperature on choroidal thickness changes will improve the reliability of the measures.
Background: It has been suggested that environmental temperature may affect choroidal thickness and blood flow, with potential implications for ocular disease and refractive development. This study investigates the effect of changes in eyelid/ocular adnexa temperature on choroidal thickness.
Methods: In a paired-eye study, 20 young, healthy subjects received a warm stimulus (heat pack) over one closed eye and simultaneously a cold stimulus (ice pack) over the other for 10 min. Eyelid temperatures were monitored with thermal probes, and optical coherence tomography scans of the retina and choroid were taken before and after heating and cooling, and then every 5 min during a 15-min recovery period. Retinal and choroidal thicknesses were measured across the macular region (6 mm), including the subfoveal (1 mm), parafoveal (1-3 mm), and perifoveal (3-5 mm) regions, and compared between the cooled and warmed eyes.
Results: When the thermal stimuli were applied, eyelid surface temperatures changed predictably and remained significantly different (by approximately 10-15°C) between the eyes after 2 min (p < .001). Relative to the warmed eye, macular choroidal thickness in the cooled eye increased significantly after 10 min of treatment (p = .004). This choroidal thickening response occurred in the subfoveal, parafoveal, and perifoveal regions (all p < .05). Upon removal of the thermal stimuli, choroidal thickness rapidly returned to the baseline and was no longer different between the cooled and warmed eye (p = .641).
Conclusion: Cooling the anterior eye by application of a cold stimulus directly onto the closed eyelid caused a small but significant increase in choroidal thickness relative to warming the anterior eye, demonstrating that the choroid can modulate its thickness rapidly and transiently in response to local temperature changes.
Keywords: Blood flow; choroid; myopia; optical coherence tomography; temperature; thickness.
Similar articles
-
Effects of tropicamide and compound tropicamide eye drops on ocular biological parameters and choroid thickness in children.BMC Ophthalmol. 2025 Jan 20;25(1):31. doi: 10.1186/s12886-025-03872-9. BMC Ophthalmol. 2025. PMID: 39833766 Free PMC article. Clinical Trial.
-
Optical coherence tomography (OCT) for detection of macular oedema in patients with diabetic retinopathy.Cochrane Database Syst Rev. 2011 Jul 6;(7):CD008081. doi: 10.1002/14651858.CD008081.pub2. Cochrane Database Syst Rev. 2011. Update in: Cochrane Database Syst Rev. 2015 Jan 07;1:CD008081. doi: 10.1002/14651858.CD008081.pub3. PMID: 21735421 Updated.
-
Optical correction of refractive error for preventing and treating eye symptoms in computer users.Cochrane Database Syst Rev. 2018 Apr 10;4(4):CD009877. doi: 10.1002/14651858.CD009877.pub2. Cochrane Database Syst Rev. 2018. PMID: 29633784 Free PMC article.
-
Active body surface warming systems for preventing complications caused by inadvertent perioperative hypothermia in adults.Cochrane Database Syst Rev. 2016 Apr 21;4(4):CD009016. doi: 10.1002/14651858.CD009016.pub2. Cochrane Database Syst Rev. 2016. PMID: 27098439 Free PMC article.
-
The correlation between intraocular pressure and choroidal microcirculation in patients with high myopia.Int J Med Sci. 2025 Jun 20;22(12):3032-3043. doi: 10.7150/ijms.113035. eCollection 2025. Int J Med Sci. 2025. PMID: 40657382 Free PMC article.