. 2024 Dec;32(12):3281-3288.
doi: 10.1002/ksa.12353. Epub 2024 Jul 17.

Trends and epidemiology in robotic-assisted total knee arthroplasty: Reduced complications and shorter hospital stays

Affiliations

Trends and epidemiology in robotic-assisted total knee arthroplasty: Reduced complications and shorter hospital stays

David Maman et al. Knee Surg Sports Traumatol Arthrosc. 2024 Dec.

Abstract

Introduction: This study provides an in-depth analysis of the immediate postoperative outcomes and implications or robotic-assisted total knee arthroplasty (RA-TKA) compared with conventional TKA (C-TKA), particularly with regard to mortality, complications, hospital stay and costs, drawing from a comprehensive nationwide data set.

Methods: The Nationwide Inpatient Sample (NIS) database, the largest all-payer inpatient healthcare database in the United States, was used to identify all patients who underwent RA-TKA or C-TKA from 2016 to 2019. A total of 527,376 cases, representing 2,638,679 patients who underwent elective TKA were identified, of which 88,415 had RA-TKA. To mitigate potential variations and selection bias in baseline characteristics between the two groups, a propensity score-matched analysis was employed to further balance and refine our data set, resulting in 176,830 patients evenly distributed between the groups. Analysis was performed according to demographics, immediate post-operative complications, and economic data, including payor class, length of stay and total charges.

Results: There was a marked shift towards RA-TKA, from an initial 0.70% in 2016 to a notable 7.30% by 2019. Patients who underwent RA-TKA were slightly younger (66.2 ± SD years), compared to the C-TKA group (66.7 ± SD years). Hospital stay was 1.89 days and 2.29 days for RA-TKA and C-TKA, respectively. Charges metrics revealed slightly higher charges for RA-TKA. Less postoperative complications were found in the RA-TKA group, such as blood loss, anaemia, acute kidney injury, venous thromboembolism, pulmonary embolism, pneumonia and surgical wound complication. Even following the propensity score matching, these findings remained consistent and statistically significant.

Conclusions: RA-TKA use in the United States has grown substantially in the last few years and has been associated with significantly reduced immediate post-operative complications and length of hospital stay compared to C-TKA, offering safer surgical management for TKA patients. Further studies on the short- and long-term outcomes of RA-TKA would improve the understanding of the full potential of this technology.

Levels of evidence: Level III.

Keywords: national inpatient sample; post‐operative complications; robotic knee surgery; total knee arthroplasty.

PubMed Disclaimer

Conflict of interest statement

The authors declare no conflicts of interest.

Figures

Figure 1
Figure 1
Percentage of robotic‐assisted total knee arthroplasty (RA‐TKA) based on the total number of TKA procedures (2016–2019). This figure illustrates the percentage of RA‐TKA procedures relative to the total number of TKA procedures performed annually between 2016 and 2019.

References

    1. Ahmed, I. , Salmon, L.J. , Waller, A. , Watanabe, H. , Roe, J.P. & Pinczewski, L.A. (2016) Total knee arthroplasty with an oxidised zirconium femoral component: ten‐year survivorship analysis. The Bone & Joint Journal, 98(1), 58–64. Available from: 10.1302/0301-620X.98B1.36314 - DOI - PubMed
    1. Barbash, G.I. & Glied, S.A. (2010) New technology and health care costs—the case of robot‐assisted surgery. New England Journal of Medicine, 363, 701–704. Available from: 10.1056/NEJMp1006602 - DOI - PubMed
    1. Cheng, R. , Kim, B. , Taylor, 4th, W.L. , Westrich, G.H. & Shen, T.S. (2024) Robotic‐assisted total knee arthroplasty is associated with the use of thinner polyethylene liners compared to navigation‐guided and manual techniques. Knee Surgery, Sports Traumatology, Arthroscopy, 1–7. Available from: 10.1002/ksa.12228 - DOI - PubMed
    1. Choi, B.S. , Kim, S.E. , Yang, M. , Ro, D.H. & Han, H.S. (2023) Functional alignment with robotic‐arm assisted total knee arthroplasty demonstrated better patient‐reported outcomes than mechanical alignment with manual total knee arthroplasty. Knee Surgery, Sports Traumatology, Arthroscopy, 31(3), 1072–1080. Available from: 10.1007/s00167-022-07227-5 - DOI - PubMed
    1. Cool, C.L. , Jacofsky, D.J. , Seeger, K.A. , Sodhi, N. & Mont, M.A. (2019) A 90‐day episode‐of‐care cost analysis of robotic‐arm assisted total knee arthroplasty. Journal of Comparative Effectiveness Research, 8(5), 327–336. Available from: 10.2217/cer-2018-0136 - DOI - PubMed