Predictors of the efficacy of His bundle pacing in patients with a prolonged PR interval: A stratified analysis of the HOPE-HF randomized controlled trial
- PMID: 39023285
- DOI: 10.1002/ejhf.3367
Predictors of the efficacy of His bundle pacing in patients with a prolonged PR interval: A stratified analysis of the HOPE-HF randomized controlled trial
Abstract
Aims: The randomized, double-blind, placebo-controlled HOPE-HF trial assessed the benefit of atrio-ventricular (AV) delay optimization delivered using His bundle pacing. It recruited patients with left ventricular ejection fraction ≤40%, PR interval ≥200 ms, and baseline QRS ≤140 ms or right bundle branch block. Overall, there was no significant increase in peak oxygen uptake (VO2max) but there was significant improvement in heart failure specific quality of life. In this pre-specified secondary analysis, we evaluated the impact of baseline PR interval, echocardiographic E-A fusion, and the magnitude of acute high-precision haemodynamic response to pacing, on outcomes.
Methods and results: All 167 randomized participants underwent measurement of PR interval, acute haemodynamic response at optimized AV delay, and assessment of presence of E-A fusion. We tested the impact of these baseline parameters using a Bayesian ordinal model on VO2max, quality of life and activity measures. There was strong evidence of a beneficial interaction between the baseline acute haemodynamic response and the blinded benefit of pacing for VO2 (Pr 99.9%), Minnesota Living With Heart Failure (MLWHF) (Pr 99.8%), MLWHF physical limitation score (Pr 98.9%), EQ-5D visual analogue scale (Pr 99.6%), and exercise time (Pr 99.4%). The baseline PR interval and the presence of baseline E-A fusion did not have this reliable ability to predict the clinical benefit of pacing over placebo across multiple endpoints.
Conclusions: In the HOPE-HF trial, the acute haemodynamic response to pacing reliably identified patients who obtained clinical benefit. Patients with a long PR interval (≥200 ms) and left ventricular impairment who obtained acute haemodynamic improvement with AV-optimized His bundle pacing were likely to obtain clinical benefit, consistent across multiple endpoints. Importantly, this gradation can be reliably tested for before randomization, but does require high-precision AV-optimized haemodynamic assessment to be performed.
Keywords: Atrio‐ventricular delay optimization; Conduction system pacing; Haemodynamic study; His bundle pacing; Physiological pacing.
© 2024 The Author(s). European Journal of Heart Failure published by John Wiley & Sons Ltd on behalf of European Society of Cardiology.
References
-
- Whinnett ZI, Shun‐Shin MJ, Tanner M, Foley P, Chandrasekaran B, Moore P, et al. Effects of haemodynamically atrio‐ventricular optimized His bundle pacing on heart failure symptoms and exercise capacity: The His Optimized Pacing Evaluated for Heart Failure (HOPE‐HF) randomized, double‐blind, cross‐over trial. Eur J Heart Fail 2023;25:274–283. https://doi.org/10.1002/ejhf.2736
-
- Shun‐Shin MJ, Miyazawa AA, Keene D, Sterlinski M, Sokal A, Van Heuverswyn F, et al. How to deliver personalized cardiac resynchronization therapy through the precise measurement of the acute hemodynamic response: Insights from the iSpot trial. J Cardiovasc Electrophysiol 2019;30:1610–1619. https://doi.org/10.1111/jce.14001
-
- Keene D, Arnold A, Shun‐Shin MJ, Howard JP, Sohaib SA, Moore P, et al. Rationale and design of the randomized multicentre His Optimized Pacing Evaluated for Heart Failure (HOPE‐HF) trial. ESC Heart Fail 2018;5:965–976. https://doi.org/10.1002/ehf2.12315
-
- R Studio Team. R Studio: Integrated Development for R RStudio. Boston, MA: PBC; 2020. http://www.rstudio.com/
-
- Harrell F. R rmsb package v1.0. https://hbiostat.org/R/rmsb/ 2023.