Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2024 Oct 15:229:1-12.
doi: 10.1016/j.amjcard.2024.07.026. Epub 2024 Jul 23.

Impact of Small Aortic Annuli on the Performance of Transcatheter Aortic Valve Replacement Bioprostheses: An Updated Meta-Analysis of Recent Studies

Affiliations
Review

Impact of Small Aortic Annuli on the Performance of Transcatheter Aortic Valve Replacement Bioprostheses: An Updated Meta-Analysis of Recent Studies

Gianluca Di Pietro et al. Am J Cardiol. .

Abstract

A metanalysis of available randomized controlled trials and observational studies comparing self-expanding (SE) and balloon-expandable (BE) bioprostheses in patients with small aortic annulus and aortic stenosis for short- and midterm hemodynamic and clinical outcomes was performed. A total of 21 studies with a total 8,647 patients (SE: n = 4,336 patients vs BE: n = 4,311 patients) were included. SE bioprostheses had a lower postoperative mean gradient at 30 days (Mean Difference [MD] -5.16, 95% confidence interval [CI] 4.7 to 5.5, p <0.001) and at 1 year (MD -6.6, 95%CI 6.1 to 7.03, p <0.001), with a larger indexed effective orifice area (0.17, 95% CI 0.13 to 0.22, p <0.001 and 0.17, 95% CI 0.08 to 0.27, p <0.001) at both time intervals. BE bioprostheses had a higher risk of 30-day and 1-year severe prosthesis-patient mismatch (risk ratio [RR] 1.07, 95% CI 1.04 to 1.09, p <0.001; RR 1.07, 95% CI 1.04 to 1.11, p <0.001). The 30-day and 1 year paravalvular leaks (RR 0.99, 95% CI 0.98 to 0.99, p <0.001; RR 0.89, 95% CI 0.82 to 0.95, p <0.001) and permanent pacemaker implantation (RR 0.97, 95% CI 0.94 to 0.99, p 0.01, I2 = 40%,) were lower in the BE group. BE bioprostheses were associated with a lower risk of in-hospital stroke (RR 0.99, 95% CI 0.98 to 1, p = 0.01). In conclusion, in patients with small aortic annulus and aortic stenosis, SE bioprostheses have superior hemodynamic performance but higher rates of paravalvular leak, permanent pacemaker implantation, and in-hospital stroke. BE bioprostheses were associated with a higher risk of severe prosthesis-patient mismatch.

Keywords: TAVR; balloon-expandable valves; bioprostheses; meta-analysis; self-expanding valves; small aortic annuli.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest Dr. Thomas Pilgrim reports research, travel or educational grants to the institution without personal remuneration from Biotronik, Boston Scientific, Edwards Lifesciences, and ATSens; speaker fees and consultancy fees to the institution from Biotronik, Boston Scientific, Edwards Lifesciences, Abbott, Medtronic, Biosensors, and Highlife. Dr. Kay Woon Ho received speaker fees from Edwards Lifesciences, Medtronic, and Abbott Vascular. The remaining authors have no competing interest to declare.

MeSH terms

LinkOut - more resources