Review
. 2024 Jul-Aug;56(6):1308-1318.
doi: 10.1016/j.transproceed.2024.05.032. Epub 2024 Jul 28.

Diagnostic and Prognostic Value of Machine Perfusion Biomarkers in Kidney Graft Evaluation

Affiliations
Review

Diagnostic and Prognostic Value of Machine Perfusion Biomarkers in Kidney Graft Evaluation

Eleni Avramidou et al. Transplant Proc. 2024 Jul-Aug.

Abstract

Background: With the rising prevalence of end-stage kidney disease, the use of expanded criteria donor allografts, seen as essential for meeting organ demand, still proves challenging due to their higher risk of graft loss, delayed function, and rejection. Machine perfusion, a technique in preserving allografts, offers improved allograft outcomes compared to static cold storage while allowing for the noninvasive measurement of kidney injury biomarkers in the perfusate solution. This offers an objective method to assess graft function at various preservation stages.

Materials and methods: We conducted a narrative review of the databases PubMed and Scopus, including studies written in the English language and published after 2010.

Results: In this narrative review, we identified biomarkers, like 4-hydroxyproline, taurine, and glutathione transferase, as predictive markers of delayed graft function. Additionally, biomarkers, like extracellular histone h3, vascular cell adhesion protein, and matrix metalloprotease protein, have shown correlation with decreased graft function, although their predictive ability remains inconclusive.

Discussion: The review outlines various suggestions for potential areas of research focus to enhance future expanded criteria donor allograft utilization. However, limitations exist, including the absence of a singular reliable biomarker and the challenges of validating biomarker effectiveness across diverse outcomes.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest All the authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.