Comparing the influence of cuspal angulation, occlusal loading, and connector widths between tooth- and implant-supported zirconia fixed dental prosthesis
- PMID: 39071759
- PMCID: PMC11280270
- DOI: 10.1016/j.mjafi.2023.10.004
Comparing the influence of cuspal angulation, occlusal loading, and connector widths between tooth- and implant-supported zirconia fixed dental prosthesis
Abstract
Background: Few studies have established the relationship between connector widths, cuspal angulation, loading forces, and supporting structures of zirconia fixed dental prosthesis (FDP). The objective of the study was to compare the stress distribution in implant- and tooth-supported zirconia FDP with different connector designs, and cuspal angulations of replaced teeth under diverse angulations of forces.
Methods: Finite element (FE) analysis was done by simulating a 3-unit implant- and tooth-supported FDP. FE models with varying cuspal angulations 0°, 20°, and 33° and connector designs 2 mm, 2.5 mm, and 3 mm was generated. The simulated models were loaded with 100 N of forces under different axial and non-axial angulations. The graphical and numerical stresses were observed, recorded, and statistically analyzed.
Results: Higher stress of 245.55 MPa in implant-supported FDP and lower stress value of 28.22 MPa in tooth-supported FDP was observed at 0-cuspal inclination for 3 mm connector width. The data were statistically analyzed with unpaired t test to eliminate the differences. The inter-group, intra-group tests, p and t values for various connector, and tooth angulations of tooth- and implant-supported FDP were statistically insignificant. (p > 0.05).
Conclusion: There was no statistically significant difference in stress was observed between tooth- and implant-supported FDP for different connector widths, cuspal inclination, and diverse angulation of forces.
Keywords: Connector; Fixed partial denture; Implant; Stress analysis; Zirconia.
© 2023 Director General, Armed Forces Medical Services. Published by Elsevier, a division of RELX India Pvt. Ltd.
Conflict of interest statement
The authors have none to declare.
Similar articles
-
Effect of connector size and configuration on the fracture resistance of a long-span implant-supported monolithic zirconia fixed partial denture (An in vitro Study).BMC Oral Health. 2025 Aug 26;25(1):1375. doi: 10.1186/s12903-025-06743-3. BMC Oral Health. 2025. PMID: 40859199 Free PMC article.
-
Retention of titanium copings to implant-supported fixed dental prostheses.J Prosthodont. 2024 Apr;33(4):340-347. doi: 10.1111/jopr.13706. Epub 2023 Jun 1. J Prosthodont. 2024. PMID: 37203989
-
Metal-free materials for fixed prosthodontic restorations.Cochrane Database Syst Rev. 2017 Dec 20;12(12):CD009606. doi: 10.1002/14651858.CD009606.pub2. Cochrane Database Syst Rev. 2017. PMID: 29261853 Free PMC article.
-
Finite Element Analysis of an Implant-Supported FDP with Different Connector Heights.Symmetry (Basel). 2022 Nov;14(11):2334. doi: 10.3390/sym14112334. Epub 2022 Nov 7. Symmetry (Basel). 2022. PMID: 40771588 Free PMC article.
-
Which mechanical and physical testing methods are relevant for predicting the clinical performance of ceramic-based dental prostheses?Clin Oral Implants Res. 2007 Jun;18 Suppl 3:218-31. doi: 10.1111/j.1600-0501.2007.01460.x. Clin Oral Implants Res. 2007. PMID: 17594384
Cited by
-
Evaluating the Impact of Pontic Geometry on Load to Failure and Displacement in Implant-Supported Monolithic Zirconia Prostheses: An In Vitro Analysis.J Funct Biomater. 2025 Feb 20;16(3):76. doi: 10.3390/jfb16030076. J Funct Biomater. 2025. PMID: 40137355 Free PMC article.
References
-
- Larsson C., Wennerberg A. The clinical success of zirconia-based crowns: a systematic review. Int J Prosthodont (IJP) 2014;27(1):33–43. - PubMed
-
- Blatz M.B., Conejo J. The current state of chairside digital dentistry and materials. Dent Clin North Am. 2019 Apr;63(2):175–197. - PubMed
-
- Tezulas E., Yildiz C., Kucuk C., Kahramanoglu E. Current status of zirconia-based all-ceramic restorations fabricated by the digital veneering technique: a comprehensive review. Int J Comput Dent. 2019;22(3):217–230. - PubMed
-
- Alghazzawi T.F. Advancements in CAD/CAM technology: options for practical implementation. J Prosthodont Res. 2016;60(2):72–84. - PubMed
LinkOut - more resources
Full Text Sources