Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2024 Jul-Aug;80(4):442-448.
doi: 10.1016/j.mjafi.2023.10.004. Epub 2023 Nov 20.

Comparing the influence of cuspal angulation, occlusal loading, and connector widths between tooth- and implant-supported zirconia fixed dental prosthesis

Affiliations

Comparing the influence of cuspal angulation, occlusal loading, and connector widths between tooth- and implant-supported zirconia fixed dental prosthesis

Naveen Gopi Chander et al. Med J Armed Forces India. 2024 Jul-Aug.

Abstract

Background: Few studies have established the relationship between connector widths, cuspal angulation, loading forces, and supporting structures of zirconia fixed dental prosthesis (FDP). The objective of the study was to compare the stress distribution in implant- and tooth-supported zirconia FDP with different connector designs, and cuspal angulations of replaced teeth under diverse angulations of forces.

Methods: Finite element (FE) analysis was done by simulating a 3-unit implant- and tooth-supported FDP. FE models with varying cuspal angulations 0°, 20°, and 33° and connector designs 2 mm, 2.5 mm, and 3 mm was generated. The simulated models were loaded with 100 N of forces under different axial and non-axial angulations. The graphical and numerical stresses were observed, recorded, and statistically analyzed.

Results: Higher stress of 245.55 MPa in implant-supported FDP and lower stress value of 28.22 MPa in tooth-supported FDP was observed at 0-cuspal inclination for 3 mm connector width. The data were statistically analyzed with unpaired t test to eliminate the differences. The inter-group, intra-group tests, p and t values for various connector, and tooth angulations of tooth- and implant-supported FDP were statistically insignificant. (p > 0.05).

Conclusion: There was no statistically significant difference in stress was observed between tooth- and implant-supported FDP for different connector widths, cuspal inclination, and diverse angulation of forces.

Keywords: Connector; Fixed partial denture; Implant; Stress analysis; Zirconia.

PubMed Disclaimer

Conflict of interest statement

The authors have none to declare.

Similar articles

Cited by

References

    1. Svanborg P. A systematic review on the accuracy of zirconia crowns and fixed dental prostheses. Biomater Investig Dent. 2020;7(1):9–15. - PMC - PubMed
    1. Larsson C., Wennerberg A. The clinical success of zirconia-based crowns: a systematic review. Int J Prosthodont (IJP) 2014;27(1):33–43. - PubMed
    1. Blatz M.B., Conejo J. The current state of chairside digital dentistry and materials. Dent Clin North Am. 2019 Apr;63(2):175–197. - PubMed
    1. Tezulas E., Yildiz C., Kucuk C., Kahramanoglu E. Current status of zirconia-based all-ceramic restorations fabricated by the digital veneering technique: a comprehensive review. Int J Comput Dent. 2019;22(3):217–230. - PubMed
    1. Alghazzawi T.F. Advancements in CAD/CAM technology: options for practical implementation. J Prosthodont Res. 2016;60(2):72–84. - PubMed

LinkOut - more resources