Abstract
Background: Glenohumeral degenerative joint disease may affect up to 20% of the population. There are several classification systems of this disease in the scientific literature.
Objective: The aim of this study is to determine the reliability and reproducibility of glenohumeral osteoarthritis classification systems.
Methods: We assessed glenohumeral plain radiographs performed in a University Hospital. These radiographs were graded into nine radiological classification systems by two observers on two evaluations. Patients who have performed CT/MRI scan were staged according to the Walch classification. The intra-observer and inter-observer reliability of the classification schemes were determined by using Cohen's weighted kappa coefficient.
Results: A total of 752 patients were included in the study (52.4% females and 47.6% males), mean aged 66.2 ± 16.3 years. The intra-observer and inter-observer reliabilities were 0.543 (observer 1), 0.630 (observer 2), and 0.760 (inter-observer) for the Weinstein grading system; 0.661, 0.706, and 0.761 for the Guyette grading system; 0.575, 0.679 and 0.704 for the Kellgren and Lawrence classification; 0.817, 0.816 e 0.871 for the Samilson and Prieto classification; 0.791, 0.811 and 0.847 for the Allain modification; 0.797, 0.842 and 0.860 for the Gerber modification; 0.773, 0.827 and 0.828 for the Buscayret modification; 0.584, 0.648 and 0.755 for the Hawkins and Angelo classification; 0.661, 0.749 and 0.764 for the Rosenberg classification. Intra-observer reliability for MRI was 0.757 (observer 1) and 0.675 (observer 2), while intra-observer reliability for CT was 0.811 (observer 1) and 0.653 (observer 2). Inter-observer reliabilities were 0.790 for MRI and 0.673 for CT.
Conclusion: The classification systems according to Weinstein, Guyette, Hawkins and Angelo, Rosenberg and the modifications of the Samilson and Prieto classification according to Allain, Gerber and Buscayret showed a comparable reliability with the commonly used glenohumeral osteoarthritis grading systems, Samilson and Prieto and Kellgren and Lawrence. Thus, they are recommended for clinical and especially scientific purposes.
Keywords: CT/MRI scan; Shoulder; Walch classification; glenohumeral osteoarthritis; radiological classifications.
Conflict of interest statement
The authors certify that there is no conflict of interest with any financial organization regarding the material discussed in the manuscript.
Figures
References
-
- Clinton J, Franta AK, Lenters TR, Mounce D, Matsen FA, 3rd. Nonprosthetic glenoid arthroplasty with humeral hemiarthroplasty and total shoulder arthroplasty yield similar self-assessed outcomes in the management of comparable patients with glenohumeral arthritis. J Shoulder Elbow Surg. 2007; 16(5): 534-8. - PubMed
-
- Moskowitz RW, Blaine TA. An overview of treatment options for persistent shoulder pain. Am J Orthop (Belle Mead NJ). 2005; 34(12 Suppl): 10-5. - PubMed
-
- Wagner ER, Farley KX, Higgins I, Wilson JM, Daly CA, Gottschalk MB. The incidence of shoulder arthroplasty: rise and future projections compared with hip and knee arthroplasty. J Shoulder Elbow Surg. 2020; 29(12): 2601-9. - PubMed
-
- Boileau P, Sinnerton RJ, Chuinard C, Walch G. Arthroplasty of the shoulder. J Bone Joint Surg Br. 2006; 88(5): 562-75. - PubMed
-
- Weinstein DM, Bucchieri JS, Pollock RG, Flatow EL, Bigliani LU. Arthroscopic debridement of the shoulder for osteoarthritis. Arthroscopy. 2000; 16(5): 471-6. - PubMed