Comparative Study
. 2024 Oct;40(10):1524-1533.
doi: 10.1016/j.dental.2024.07.014. Epub 2024 Aug 5.

Do all ceramic and composite CAD-CAM materials exhibit equal bonding properties to implant Ti-base materials? An Interfacial Fracture Toughness Study

Affiliations
Free article
Comparative Study

Do all ceramic and composite CAD-CAM materials exhibit equal bonding properties to implant Ti-base materials? An Interfacial Fracture Toughness Study

Yousef Karevan et al. Dent Mater. 2024 Oct.
Free article

Abstract

Objectives: To compare the interfacial fracture toughness (IFT) with or without aging, of four different classes of CAD-CAM ceramic and composite materials bonded with self-adhesive resin cement to titanium alloy characteristic of implant abutments.

Methods: High translucent zirconia (Katana; KAT), lithium disilicate-based glass-ceramic (IPS. emax.CAD; EMX), polymer-infiltrated ceramic network material (PICN) (Vita Enamic; ENA), and dispersed filler composite (Cerasmart 270; CER) were cut into equilateral triangular prisms and bonded to titanium prisms with identical dimensions using Panavia SA Cement Universal. The surfaces were pretreated following the manufacturers' recommendations and developed interfacial area ratio (Sdr) of the pretreated surfaces was measured. IFT was determined using the Notchless Triangular Prism test in a water bath at 36 °C before and after thermocycling (10,000 cycles) (n = 40 samples/material).

Results: IFT of the materials ranged from 0.80 ± 0.25 to 1.10 ± 0.21 MPa.m1/2 before thermocycling and from 0.71 ± 0.24 to 1.02 ± 0.25 MPa.m1/2 after thermocycling. There was a statistical difference between IFT of CER and the two top performers in each scenario: KAT and EMX before aging, and KAT and ENA after aging. Thermocycling significantly decreased IFT of EMX. The Weibull modulus of IFT was similar for all materials and remained so after thermocycling. Sdr measurements revealed that ENA (7.60)>Ti (4.97)>CER (2.85)>KAT (1.09)=EMX (0.96).

Significance: Dispersed filler CAD-CAM composite showed lower performance than the other materials. Aging only affected IFT of Li-Si glass-ceramic, whereas zirconia and PICN performed equally well, probably due to their chemical bonding potential and surface roughness respectively.

Keywords: Adhesion; Cementation; Dental materials; Fracture mechanics; Hybrid ceramics; Implant prostheses; Prosthetic dentistry.

PubMed Disclaimer

Publication types