Multicenter Study
. 2024 Aug 8;31(4):e0981.
doi: 10.1097/LBR.0000000000000981. eCollection 2024 Oct 1.

Shape-sensing Robotic-assisted Bronchoscopy (SS-RAB) in Sampling Peripheral Pulmonary Nodules: A Prospective, Multicenter Clinical Feasibility Study in China

Affiliations
Multicenter Study

Shape-sensing Robotic-assisted Bronchoscopy (SS-RAB) in Sampling Peripheral Pulmonary Nodules: A Prospective, Multicenter Clinical Feasibility Study in China

Fangfang Xie et al. J Bronchology Interv Pulmonol. .

Abstract

Background: The ION system is a shape-sensing robotic-assisted bronchoscopy (SS-RAB) platform developed to biopsy peripheral pulmonary nodules (PPNs). There is a lack of data describing the use of this system in the Chinese population. The study aimed to assess the feasibility and safety of using SS-RAB to diagnose PPNs across multiple centers within China.

Methods: This prospective, multicenter study used SS-RAB in consecutive patients with solid or sub-solid PPNs 8 to 30 mm in largest diameter. Primary endpoints were diagnostic yield and the rates of procedure- or device-related complications. Radial endobronchial ultrasound (rEBUS) was to confirm lesion localization, followed by sampling, using the Flexision biopsy needle, biopsy forceps, and cytology brush. Subjects with nonmalignant index biopsy results were followed up to 6 months.

Results: A total of 90 PPNs were biopsied from 90 subjects across 3 centers using SS-RAB. The median nodule size was 19.4 mm (IQR: 19.3, 24.6) in the largest dimension. In all (100%) cases, the catheter successfully reached the target nodule with tissue samples obtained. The diagnostic yield was 87.8% with a sensitivity for malignancy of 87.7% (71/81). In a univariate analysis, nodule lobar location, presence of bronchus sign, and rEBUS view were associated with a diagnostic sample, but only rEBUS view showed an association in a multivariate analysis. The overall pneumothorax rate was 1.1% without pneumothorax requiring intervention, and there was no periprocedural bleeding.

Conclusion: As an emerging technology in the Chinese population, SS-RAB can safely biopsy PPNs with strong diagnostic performance.

PubMed Disclaimer

Conflict of interest statement

Disclosure: M.J.S. is a pulmonologist at Henry Ford Hospital, Wayne State University School of Medicine, and serves as the associate medical officer of Ion Robotic Systems, Intuitive Surgical, Inc. as well. For the remaining authors, there are no conflicts of interest or other disclosures.

References

    1. Sung H, Ferlay J, Siegel RL, et al. Global cancer statistics 2020: Globocan estimates of incidence and mortality worldwide for 36 cancers in 185 countries. CA Cancer J Clin. 2021;71:209–249.
    1. Oudkerk M, Liu S, Heuvelmans MA, et al. Lung cancer ldct screening and mortality reduction—evidence, pitfalls and future perspectives. Nat Rev Clin Oncol. 2021;18:135–151.
    1. de Koning HJ, van der Aalst CM, de Jong PA, et al. Reduced lung-cancer mortality with volume CT screening in a randomized trial. N Engl J Med. 2020;382:503–513.
    1. Nadig TR, Thomas N, Nietert PJ, et al. Guided bronchoscopy for the evaluation of pulmonary lesions: an updated meta-analysis. Chest. 2023;163:1589–1598.
    1. Reisenauer J, Simoff MJ, Pritchett MA, et al. Ion: Technology and techniques for shape-sensing robotic-assisted bronchoscopy. Ann Thorac Surg. 2022;113:308–315.

Publication types

MeSH terms