Review
. 2024 Jul 23;14(15):1585.
doi: 10.3390/diagnostics14151585.

An Analysis of Computed Tomography Diagnostic Reference Levels in India Compared to Other Countries

Affiliations
Review

An Analysis of Computed Tomography Diagnostic Reference Levels in India Compared to Other Countries

Maajid Mohi Ud Din Malik et al. Diagnostics (Basel). .

Abstract

Computed Tomography (CT) is vital for diagnosing and monitoring medical conditions. However, increased usage raises concerns about patient radiation exposure. Diagnostic Reference Levels (DRLs) aim to minimize radiation doses in CT imaging. This study examines CT DRLs in India compared to other countries to identify optimization opportunities. A literature review was conducted to gather data from published studies, guidelines, and regulatory authorities. Findings show significant international variations in CT DRLs, with differences up to 50%. In India, DRLs also vary significantly across states. For head CT exams, Indian DRLs are generally 20-30% lower than international standards (27-47 mGy vs. 60 mGy). Conversely, for abdominal CT scans, Indian DRLs are 10-15% higher (12-16 mGy vs. 13 mGy). Factors influencing DRL variations include equipment differences, imaging protocols, patient demographics, and regulatory conditions. Dose-optimization techniques like automatic exposure control and iterative reconstruction can reduce radiation exposure by 25-60% while maintaining image quality. Comparative data highlight best practices, such as the United Kingdom's 30% reduction in CT doses from 1984 to 1995 via DRL implementation. This study suggests that adopting similar practices in India could reduce radiation doses by 20-40% for common CT procedures, promoting responsible CT usage and minimizing patient exposure.

Keywords: CT dose index; computed tomography; diagnostic reference level; dose-length product.

PubMed Disclaimer

Conflict of interest statement

The authors declare no conflict of interest.

References

    1. UNSCEAR . Sources, Effects and Risks of Ionizing Radiation. United Nations Scientific Committee on the Effects of Atomic Radiation. Report to the General Assembly with Scientific Annexes. UNSCEAR; Vienna, Austria: 2008. U.N. Publication.
    1. ICRP . Diagnostic Reference Levels in Medical Imaging. Volume 46. ICRP; Stockholm, Sweden: 2017. pp. 1–147. ICRP Publication 135. - DOI - PubMed
    1. American Association of Physicists in Medicine . Size-Specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations. AAPM; Alexandria, VA, USA: 2011. AAPM Report No 204.
    1. Kanal K.M., Butler P.F., Sengupta D., Bhargavan-Chatfield M., Coombs L.P., Morin R.L. U. S. diagnostic reference levels and achievable doses for 10 adult CT examinations. Radiology. 2017;284:120–133. doi: 10.1148/radiol.2017161911. - DOI - PubMed
    1. European Commission . European Guidelines on Diagnostic Reference Levels for Paediatric Imaging. Radiation Protection No 185. Directorate-General for Energy Directorate D-Nuclear Energy, Safety and ITER Unit D3-Radiation Protection and Nuclear Safety 2018. European Union; Luxembourg: 2018. pp. 1–122.

LinkOut - more resources