. 2024 Sep:174:112261.
doi: 10.1016/j.jbiomech.2024.112261. Epub 2024 Aug 5.

Reliability of cervicocephalic sense of force

Affiliations
Free article

Reliability of cervicocephalic sense of force

Daniel J English et al. J Biomech. 2024 Sep.
Free article

Abstract

Cervicocephalic proprioception (CCP) is an important assessment item for people with a range of clinical conditions, where reduced CCP is associated with neck pain and imbalance. Reliability has been established for a range of positional and movements tests, but there is limited data regarding sense of force, particularly across three planes of movement. The current test-retest study assessed reliability when evaluating sense of force in healthy adults (8 males, 6 females, mean age 31.50 years [SD 10.14]) over two sessions, 4-7 days apart. A force matching protocol was used to evaluate reliability of absolute error (AE), constant error (CE), and variable error (VE) for 10 % and 25 % maximal voluntary contraction (MVC) target forces for flexion, extension, lateral flexion, and rotation. Participants were strapped to a chair to limit trunk movement and data was captured using a compressive force transducer fixed to an adjustable wall mount. Six trials were performed for each contraction-type, totaling 72 submaximal MVCs per session. ICC estimates for AE (0.15-0.77), CE (0.01-0.85), and VE (0.00-0.83) were varied and confidence intervals were mostly wide. Considering lower limits of confidence intervals, CE had best reliability values generally, but more specifically the most reliable contraction type and movement was 25 % MVC flexion (ICC 0.85, confidence interval 0.54-0.95). This study found that reliability for sense of force testing was dependent upon contraction, type of error, and target force utilized. Further reliability analysis should be performed when applying this test to measure validity outcomes in clinical populations.

Keywords: Assessment; Cervical; Clinical; Force; Proprioception; Reliability.