DeepEMC-T2 mapping: Deep learning-enabled T2 mapping based on echo modulation curve modeling
- PMID: 39129209
- PMCID: PMC11436299
- DOI: 10.1002/mrm.30239
DeepEMC-T2 mapping: Deep learning-enabled T2 mapping based on echo modulation curve modeling
Abstract
Purpose: Echo modulation curve (EMC) modeling enables accurate quantification of T2 relaxation times in multi-echo spin-echo (MESE) imaging. The standard EMC-T2 mapping framework, however, requires sufficient echoes and cumbersome pixel-wise dictionary-matching steps. This work proposes a deep learning version of EMC-T2 mapping, called DeepEMC-T2 mapping, to efficiently estimate accurate T2 maps from fewer echoes.
Methods: DeepEMC-T2 mapping was developed using a modified U-Net to estimate both T2 and proton density (PD) maps directly from MESE images. The network implements several new features to improve the accuracy of T2/PD estimation. A total of 67 MESE datasets acquired in axial orientation were used for network training and evaluation. An additional 57 datasets acquired in coronal orientation with different scan parameters were used to evaluate the generalizability of the framework. The performance of DeepEMC-T2 mapping was evaluated in seven experiments.
Results: Compared to the reference, DeepEMC-T2 mapping achieved T2 estimation errors from 1% to 11% and PD estimation errors from 0.4% to 1.5% with ten/seven/five/three echoes, which are more accurate than standard EMC-T2 mapping. By incorporating datasets acquired with different scan parameters and orientations for joint training, DeepEMC-T2 exhibits robust generalizability across varying imaging protocols. Increasing the echo spacing and including longer echoes improve the accuracy of parameter estimation. The new features proposed in DeepEMC-T2 mapping all enabled more accurate T2 estimation.
Conclusions: DeepEMC-T2 mapping enables simplified, efficient, and accurate T2 quantification directly from MESE images without dictionary matching. Accurate T2 estimation from fewer echoes allows for increased volumetric coverage and/or higher slice resolution without prolonging total scan times.
Keywords: T2 mapping; deep learning; echo modulation curve; multi‐echo spin‐echo; quantitative MRI.
© 2024 International Society for Magnetic Resonance in Medicine.
Similar articles
-
Single-shot T2 mapping via multi-slice information sharing based on switching modulation patterns multiple overlapping-echo detachment imaging.Med Phys. 2025 Jun;52(6):4464-4479. doi: 10.1002/mp.17778. Epub 2025 Mar 24. Med Phys. 2025. PMID: 40129089
-
Quantitative platform for accurate and reproducible assessment of transverse (T2 ) relaxation time.NMR Biomed. 2021 Aug;34(8):e4537. doi: 10.1002/nbm.4537. Epub 2021 May 16. NMR Biomed. 2021. PMID: 33993573
-
Streamlined magnetic resonance fingerprinting: Fast whole-brain coverage with deep-learning based parameter estimation.Neuroimage. 2021 Sep;238:118237. doi: 10.1016/j.neuroimage.2021.118237. Epub 2021 Jun 5. Neuroimage. 2021. PMID: 34091035
-
Mitigating slice cross-talk in multi-slice multi-echo spin echo T2 mapping.Magn Reson Med. 2024 May;91(5):2089-2103. doi: 10.1002/mrm.29987. Epub 2023 Dec 29. Magn Reson Med. 2024. PMID: 38156822
-
A simultaneous multi-slice T2 mapping framework based on overlapping-echo detachment planar imaging and deep learning reconstruction.Magn Reson Med. 2022 May;87(5):2239-2253. doi: 10.1002/mrm.29128. Epub 2022 Jan 11. Magn Reson Med. 2022. PMID: 35014727
Cited by
-
Accelerated free-breathing abdominal T2 mapping with deep learning reconstruction of radial turbo spin-echo data.Magn Reson Med. 2025 Aug 5:10.1002/mrm.70017. doi: 10.1002/mrm.70017. Online ahead of print. Magn Reson Med. 2025. PMID: 40762149 Free PMC article.
References
-
- Poon Colin S., and Henkelman R. Mark. “Practical T2 quantitation for clinical applications.” Journal of Magnetic Resonance Imaging 2.5 (1992): 541–553. - PubMed
-
- Bauer Sonja, et al. “Quantitative T2′-mapping in acute ischemic stroke.” Stroke 45.11 (2014): 3280–3286. - PubMed
-
- Surowiec Rachel K., Lucas Erin P., and Ho Charles P.. “Quantitative MRI in the evaluation of articular cartilage health: reproducibility and variability with a focus on T2 mapping.” Knee Surgery, Sports Traumatology, Arthroscopy 22 (2014): 1385–1395. - PubMed
MeSH terms
Grants and funding
- R21 EB032917/EB/NIBIB NIH HHS/United States
- R21 EB031185/EB/NIBIB NIH HHS/United States
- R21EB032917/NH/NIH HHS/United States
- R01 AR079442/AR/NIAMS NIH HHS/United States
- R01 EB030549/EB/NIBIB NIH HHS/United States
- R01EB030549/NH/NIH HHS/United States
- R01AR081344/NH/NIH HHS/United States
- R01 AR081344/AR/NIAMS NIH HHS/United States
- P41EB017183/NH/NIH HHS/United States
- R01AR079442/NH/NIH HHS/United States
- P41 EB017183/EB/NIBIB NIH HHS/United States
- R21EB031185/NH/NIH HHS/United States
- R01 EB031083/EB/NIBIB NIH HHS/United States
LinkOut - more resources
Full Text Sources
Medical