. 2024 Feb 23;3(4):101343.
doi: 10.1016/j.jscai.2024.101343. eCollection 2024 Apr.

Efficacy of the Direct Wire Pacing Technique During a TAVR Through a Simple Electrocautery Plate

Affiliations

Efficacy of the Direct Wire Pacing Technique During a TAVR Through a Simple Electrocautery Plate

Patrice Guerin et al. J Soc Cardiovasc Angiogr Interv. .
No abstract available

Keywords: electrocautery plate; guidewire; pacing; transcatheter aortic valve replacement.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Set up in the cath lab for the direct wire pacing technique using an electrocautery plate. Anode connected to the electrocautery plate. Cathode connected to the distal external end of the guide wire positioned in the left ventricle. Figure created by P.G. Piriou, based on work by S. Raeder.

References

    1. Burzotta F., Aurigemma C., Romagnoli E., et al. A less-invasive totally-endovascular (LITE) technique for trans-femoral transcatheter aortic valve replacement. Catheter Cardiovasc Interv. 2020;96(2):459–470. doi: 10.1002/ccd.28697. - DOI - PubMed
    1. Lefèvre G., Jégou A., Dambrin G., et al. Comparison of transfemoral transcatheter aortic valve replacement performed with a minimally invasive simplified technique: “FAST” versus a standard approach. J Invasive Cardiol. 2019;31(10):300–306. - PubMed
    1. Meier B., Rutishauser W. Coronary pacing during percutaneous transluminal coronary angioplasty. Circulation. 1985;71(3):557–561. doi: 10.1161/01.CIR.71.3.557. - DOI - PubMed
    1. Faurie B., Souteyrand G., Staat P., et al. Left ventricular rapid pacing via the valve delivery guidewire in transcatheter aortic valve replacement. J Am Coll Cardiol Intv. 2019;12(24):2449–2459. doi: 10.1016/j.jcin.2019.09.029. - DOI - PubMed
    1. Blusztein D., Raney A., Walsh J., Nazif T., Woods C., Daniels D. Best practices in left ventricular pacing for transcatheter aortic valve replacement. Struct Heart. 2023;7(6) doi: 10.1016/j.shj.2023.100213. - DOI - PMC - PubMed