Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2024 Nov;138(6):2299-2314.
doi: 10.1007/s00414-024-03308-x. Epub 2024 Aug 13.

Validation of the PowerPlex®35GY System: a novel eight-dye STR multiplex kit on the Spectrum Compact CE System

Affiliations

Validation of the PowerPlex®35GY System: a novel eight-dye STR multiplex kit on the Spectrum Compact CE System

Weifeng Qu et al. Int J Legal Med. 2024 Nov.

Abstract

The PowerPlex® 35GY System (Promega, USA) is an advanced eight-dye multiplex STR kit, incorporating twenty-three autosomal STR loci, eleven Y chromosome STR loci, one sex determining marker Amelogenin, and two quality indicators. This multiplex system includes 20 CODIS loci and up to 15 mini-STR loci with sizing values less than 250 bases. In this study, validation for PowerPlex® 35GY System was conducted following the guidelines of SWGDAM, encompassing sensitivity, precision, accuracy, concordance, species specificity, stutter, mixture, stability, and degraded DNA. The results from experiments demonstrated that the PowerPlex® 35GY System could effectively amplify DNA samples, with complete allele detection achieved at 125 pg. Moreover, over 90% of alleles from minor contributors were detected at a mixed ratio of 1:4. Additionally, the system was found to yield full profiles even in the presence of hematin, humic acid, and indigo. The PowerPlex® 35GY System demonstrated superior performance in the sensitivity and degraded DNA studies compared to a six-dye STR kit. Hence, it is evident that the PowerPlex® 35GY System is well-suited for forensic practice, whether in casework or for database samples. These findings provide strong support for the efficacy and reliability of the PowerPlex® 35GY System in forensic applications.

Keywords: 8-dye chemistry; Forensic science; PowerPlex® 35GY System; Short tandem repeat; Spectrum Compact CE System; Validation.

PubMed Disclaimer

References

    1. Butler JM (2012) Advanced topics in forensic DNA typing: methodology. Elsevier/Academic
    1. Butler JM (2022) Recent advances in forensic biology and forensic DNA typing: INTERPOL review 2019–2022. Forensic Sci Int Synerg 6:100311. https://doi.org/10.1016/j.fsisyn.2022.100311 - DOI - PubMed - PMC
    1. Wang DY, Chang CW, Lagacé RE, Calandro LM, Hennessy LK (2012) Developmental validation of the AmpFℓSTR® Identifiler® Plus PCR amplification kit: an established multiplex assay with improved performance. J Forensic Sci 57(2):453–465. https://doi.org/10.1111/j.1556-4029.2011.01963.x - DOI - PubMed
    1. Green R, Elliott JL, Norona W et al (2021) Developmental validation of VeriFiler™ plus PCR amplification kit: a 6-dye multiplex assay designed for casework samples. Forensic Sci Int Genet 53:102494. https://doi.org/10.1016/j.fsigen.2021.102494 - DOI - PubMed
    1. Li J, Luo H, Song F et al (2017) Validation of the Microreader™ 23sp ID system: a new STR 23-plex system for forensic application. Forensic Sci Int Genet 27:67–73. https://doi.org/10.1016/j.fsigen.2016.12.005 - DOI - PubMed

Publication types

LinkOut - more resources