Validation of the PowerPlex®35GY System: a novel eight-dye STR multiplex kit on the Spectrum Compact CE System
- PMID: 39134883
- DOI: 10.1007/s00414-024-03308-x
Validation of the PowerPlex®35GY System: a novel eight-dye STR multiplex kit on the Spectrum Compact CE System
Abstract
The PowerPlex® 35GY System (Promega, USA) is an advanced eight-dye multiplex STR kit, incorporating twenty-three autosomal STR loci, eleven Y chromosome STR loci, one sex determining marker Amelogenin, and two quality indicators. This multiplex system includes 20 CODIS loci and up to 15 mini-STR loci with sizing values less than 250 bases. In this study, validation for PowerPlex® 35GY System was conducted following the guidelines of SWGDAM, encompassing sensitivity, precision, accuracy, concordance, species specificity, stutter, mixture, stability, and degraded DNA. The results from experiments demonstrated that the PowerPlex® 35GY System could effectively amplify DNA samples, with complete allele detection achieved at 125 pg. Moreover, over 90% of alleles from minor contributors were detected at a mixed ratio of 1:4. Additionally, the system was found to yield full profiles even in the presence of hematin, humic acid, and indigo. The PowerPlex® 35GY System demonstrated superior performance in the sensitivity and degraded DNA studies compared to a six-dye STR kit. Hence, it is evident that the PowerPlex® 35GY System is well-suited for forensic practice, whether in casework or for database samples. These findings provide strong support for the efficacy and reliability of the PowerPlex® 35GY System in forensic applications.
Keywords: 8-dye chemistry; Forensic science; PowerPlex® 35GY System; Short tandem repeat; Spectrum Compact CE System; Validation.
© 2024. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.
References
-
- Butler JM (2012) Advanced topics in forensic DNA typing: methodology. Elsevier/Academic
-
- Butler JM (2022) Recent advances in forensic biology and forensic DNA typing: INTERPOL review 2019–2022. Forensic Sci Int Synerg 6:100311. https://doi.org/10.1016/j.fsisyn.2022.100311 - DOI - PubMed - PMC
-
- Wang DY, Chang CW, Lagacé RE, Calandro LM, Hennessy LK (2012) Developmental validation of the AmpFℓSTR® Identifiler® Plus PCR amplification kit: an established multiplex assay with improved performance. J Forensic Sci 57(2):453–465. https://doi.org/10.1111/j.1556-4029.2011.01963.x - DOI - PubMed
-
- Green R, Elliott JL, Norona W et al (2021) Developmental validation of VeriFiler™ plus PCR amplification kit: a 6-dye multiplex assay designed for casework samples. Forensic Sci Int Genet 53:102494. https://doi.org/10.1016/j.fsigen.2021.102494 - DOI - PubMed
-
- Li J, Luo H, Song F et al (2017) Validation of the Microreader™ 23sp ID system: a new STR 23-plex system for forensic application. Forensic Sci Int Genet 27:67–73. https://doi.org/10.1016/j.fsigen.2016.12.005 - DOI - PubMed
Publication types
MeSH terms
Substances
Grants and funding
- 82271928/National Natural Science Foundation of China
- 82230064/Key Program National Natural Science Foundation of China
- 2023YFF0614604/National Key Research and Development Program of China
- 2021YFC3300104/National Key Research and Development Program of China
- JYFY-23KF005/Hebei Province Key Laboratory of Forensic Medicine Open Project