Twenty patients were studied on a bicycle ergometer at rest and at varying workloads to compare methods of measuring cardiac output. In nine patients, a comparison of carbon dioxide rebreathing and dye dilution techniques for measuring cardiac output were made. In eleven patients, comparisons between carbon dioxide rebreathing, dye dilution, and direct oxygen Fick techniques were made. The cardiac output measured by carbon dioxide rebreathing was reproducible and compared well with both the dye dilution and direct oxygen Fick. The correlation coefficient for the relationship between carbon dioxide rebreathing and direct oxygen Fick cardiac outputs was 0.80 and between carbon dioxide rebreathing and dye dilution cardiac outputs was 0.75. The relationship between dye dilution and direct oxygen Fick cardiac output was 0.71. The carbon dioxide rebreathing technique is a safe, non-invasive and reproducible method to measure cardiac output. The results compare well with the cardiac output measured by either the direct oxygen Fick or dye dilution technique.
Similar articles
-
Validation of the CO2 rebreathing method for measuring cardiac output in patients with hypertension or heart failure.J Lab Clin Med. 1976 Oct;88(4):672-82. J Lab Clin Med. 1976. PMID: 787459 Clinical Trial.
-
[Non-invasive measurement of cardiac output by the CO2 rebreathing method and its reliability in clinical practice].Kokyu To Junkan. 1991 Jun;39(6):579-85. Kokyu To Junkan. 1991. PMID: 1908114 Japanese.
-
Automated non-invasive measurement of cardiac output by the carbon dioxide rebreathing method: comparisons with dye dilution and thermodilution.Br Heart J. 1990 Mar;63(3):195-9. doi: 10.1136/hrt.63.3.195. Br Heart J. 1990. PMID: 2109625 Free PMC article.
-
Measurement of cardiac output by carbon dioxide rebreathing methods.Clin Chest Med. 1989 Jun;10(2):255-64. Clin Chest Med. 1989. PMID: 2500297 Review.
-
Noninvasive monitoring cardiac output using partial CO(2) rebreathing.Crit Care Clin. 2010 Apr;26(2):383-92, table of contents. doi: 10.1016/j.ccc.2009.12.002. Crit Care Clin. 2010. PMID: 20381727 Review.
Cited by
-
Non-invasive assessment of cardiac output and stroke volume in patients during exercise. Evaluation of a CO2-rebreathing method.Eur J Appl Physiol Occup Physiol. 1986;55(5):538-44. doi: 10.1007/BF00421650. Eur J Appl Physiol Occup Physiol. 1986. PMID: 3095112
-
Comparison and reliability of two non-invasive acetylene uptake techniques for the measurement of cardiac output.Eur J Appl Physiol. 2005 Aug;94(5-6):670-80. doi: 10.1007/s00421-005-1343-2. Epub 2005 May 26. Eur J Appl Physiol. 2005. PMID: 15918060 Clinical Trial.
-
Reliability and validity of measures of cardiac output during incremental to maximal aerobic exercise. Part I: Conventional techniques.Sports Med. 1999 Jan;27(1):23-41. doi: 10.2165/00007256-199927010-00003. Sports Med. 1999. PMID: 10028131 Review.
-
The influence of hyperventilation on the measurement of stroke volume using a CO2 rebreathing method.Eur J Appl Physiol Occup Physiol. 1986;55(1):19-23. doi: 10.1007/BF00422887. Eur J Appl Physiol Occup Physiol. 1986. PMID: 3084237 Clinical Trial.