No Difference in 10-year Clinical or Radiographic Outcomes Between Kinematic and Mechanical Alignment in TKA: A Randomized Trial
- PMID: 39145997
- PMCID: PMC11658733
- DOI: 10.1097/CORR.0000000000003193
No Difference in 10-year Clinical or Radiographic Outcomes Between Kinematic and Mechanical Alignment in TKA: A Randomized Trial
Abstract
Background: There is continuing debate about the ideal philosophy for component alignment in TKA. However, there are limited long-term functional and radiographic data on randomized comparisons of kinematic alignment versus mechanical alignment.
Questions/purposes: We present the 10-year follow-up findings of a single-center, multisurgeon randomized controlled trial (RCT) comparing these two alignment philosophies in terms of the following questions: (1) Is there a difference in PROM scores? (2) Is there a difference in survivorship free from revision or reoperation for any cause? (3) Is there a difference in survivorship free from radiographic loosening?
Methods: Ninety-nine patients undergoing primary TKA for osteoarthritis were randomized to either the mechanical alignment (n = 50) or kinematic alignment (n = 49) group. Eligibility for the study was patients undergoing unilateral TKA for osteoarthritis who were suitable for a cruciate-retaining TKA and could undergo MRI. Patients who had previous osteotomy, coronal alignment > 15° from neutral, a fixed flexion deformity > 15°, or instability whereby constrained components were being considered were excluded. Computer navigation was used in the mechanical alignment group, and patient-specific cutting blocks were used in the kinematic alignment group. At 10 years, 86% (43) of the patients in the mechanical alignment group and 80% (39) in the kinematic alignment group were available for follow-up performed as a per-protocol analysis. The PROMs that we assessed included the Knee Society Score, Oxford Knee Score, WOMAC, Forgotten Joint Score, and EuroQol 5-Dimension score. Kaplan-Meier analysis was used to assess survivorship free from reoperation (any reason) and revision (change or addition of any component). A single blinded observer assessed radiographs for signs of aseptic loosening (as defined by the presence of progressive radiolucent lines in two or more zones), which was reported as survivorship free from loosening.
Results: At 10 years, there was no difference in any PROM score measured between the groups. Ten-year survivorship free from revision (components removed or added) likewise did not differ between the groups (96% [95% CI 91% to 99%] for the mechanical alignment group and 91% [95% CI 83% to 99%] for the kinematic alignment group; p = 0.38). There were two revisions in the mechanical alignment group (periprosthetic fracture, deep infection) and four in the kinematic alignment group (two secondary patella resurfacings, two deep infections). There was no statistically significant difference in reoperations for any cause between the two groups. There was no difference with regard to survivorship free from loosening on radiographic review (χ 2 = 1.3; p = 0.52) (progressive radiolucent lines seen at 10 years were 0% for mechanical alignment and 3% for kinematic alignment).
Conclusion: Like the 2-year and 5-year outcomes previously reported, 10-year follow-up for this RCT demonstrated no functional or radiographic difference in outcomes between mechanical alignment and kinematic alignment TKA. Anticipated functional benefits of kinematic alignment were not demonstrated, and revision-free survivorship at 10 years did not differ between the two groups. Given the unknown long-term impact of kinematic alignment with regard to implant position (especially tibial component varus), we must conclude that mechanical alignment remains the reference standard for TKA. We could not demonstrate any advantage to kinematic alignment at 10-year follow-up.
Level of evidence: Level I, therapeutic study.
Copyright © 2024 by the Association of Bone and Joint Surgeons.
Conflict of interest statement
All ICMJE Conflict of Interest Forms for authors and Clinical Orthopaedics and Related Research® editors and board members are on file with the publication and can be viewed on request.
Similar articles
-
Kinematic Alignment Does Not Result in Clinically Important Improvements After TKA Compared With Mechanical Alignment: A Meta-analysis of Randomized Trials.Clin Orthop Relat Res. 2025 Jun 1;483(6):1020-1030. doi: 10.1097/CORR.0000000000003356. Epub 2025 Jan 21. Clin Orthop Relat Res. 2025. PMID: 39842026
-
What Are the Functional, Radiographic, and Survivorship Outcomes of a Modified Cup-cage Technique for Pelvic Discontinuity?Clin Orthop Relat Res. 2024 Dec 1;482(12):2149-2160. doi: 10.1097/CORR.0000000000003186. Epub 2024 Jul 9. Clin Orthop Relat Res. 2024. PMID: 38991223
-
What Is the Survivorship of TKA With a Twin-peg or Spikes-and-keel Cementless Implant Compared With Cemented? A Registry-based Cohort Study.Clin Orthop Relat Res. 2025 Feb 5;483(7):1288-1298. doi: 10.1097/CORR.0000000000003385. Clin Orthop Relat Res. 2025. PMID: 39915112
-
Robotic Assistance Is Not Associated With Decreased Early Revisions in Cementless TKA: An Analysis of the American Joint Replacement Registry.Clin Orthop Relat Res. 2025 Mar 1;483(3):431-438. doi: 10.1097/CORR.0000000000003330. Epub 2024 Nov 21. Clin Orthop Relat Res. 2025. PMID: 39569799
-
Are There Differences in Accuracy or Outcomes Scores Among Navigated, Robotic, Patient-specific Instruments or Standard Cutting Guides in TKA? A Network Meta-analysis.Clin Orthop Relat Res. 2020 Sep;478(9):2105-2116. doi: 10.1097/CORR.0000000000001324. Clin Orthop Relat Res. 2020. PMID: 32530896 Free PMC article.
Cited by
-
Lateral Instability 13 Years After Kinematically Aligned Total Knee Arthroplasty.Arthroplast Today. 2025 Apr 12;33:101674. doi: 10.1016/j.artd.2025.101674. eCollection 2025 Jun. Arthroplast Today. 2025. PMID: 40276528 Free PMC article.
-
Caliper verification and gap measurements of kinematic alignment total knee arthroplasty utilizing an imageless, accelerometer-based navigation system.Knee Surg Relat Res. 2025 Feb 17;37(1):8. doi: 10.1186/s43019-025-00260-x. Knee Surg Relat Res. 2025. PMID: 39962595 Free PMC article.
-
CORR Insights®: No Difference in 10-year Clinical or Radiographic Outcomes Between Kinematic and Mechanical Alignment in TKA: A Randomized Trial.Clin Orthop Relat Res. 2025 Jan 1;483(1):150-151. doi: 10.1097/CORR.0000000000003229. Epub 2024 Aug 19. Clin Orthop Relat Res. 2025. PMID: 39162658 No abstract available.
-
Clinical outcomes of kinematically aligned medial pivot total knee arthroplasty: A systematic review and meta-analysis of current evidence.J Exp Orthop. 2025 Jul 13;12(3):e70348. doi: 10.1002/jeo2.70348. eCollection 2025 Jul. J Exp Orthop. 2025. PMID: 40655242 Free PMC article. Review.
References
-
- Behrend H, Giesinger K, Giesinger JM, Kuster MS. The “forgotten joint” as the ultimate goal in joint arthroplasty. J Arthroplasty. 2012;27:430-436.e1. - PubMed
-
- Berend ME, Ritter MA, Meding JB, et al. Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res. 2004;428:26-34. - PubMed
-
- Blackburn J, Qureshi A, Amirfeyz R, Bannister G. Does preoperative anxiety and depression predict satisfaction after total knee replacement? Knee. 2012;19:522-524. - PubMed
-
- Brar AS, Howell SM, Hull ML, Mahfouz MR. Does kinematic alignment and flexion of a femoral component designed for mechanical alignment reduce the proximal and lateral reach of the trochlea? J Arthroplasty. 2016;31:1808-1813. - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials