Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2025 Jan;57(1):41-48.
doi: 10.1055/a-2368-4608. Epub 2024 Aug 28.

Endoscopic ultrasound-guided versus percutaneous liver biopsy: a systematic review and meta-analysis of randomized controlled trials

Affiliations
Meta-Analysis

Endoscopic ultrasound-guided versus percutaneous liver biopsy: a systematic review and meta-analysis of randomized controlled trials

Paula Arruda do Espirito Santo et al. Endoscopy. 2025 Jan.

Abstract

Background: Percutaneous liver biopsy (PC-LB) has long been the usual method for acquisition of liver tissue. Recently, endoscopic ultrasound-guided liver biopsy (EUS-LB) has gained popularity as an alternative modality. We aimed to compare the efficacy and safety of EUS-LB versus PC-LB.

Methods: We systematically searched PubMed, Embase, and the Cochrane Library databases for randomized controlled trials (RCTs) comparing EUS-LB with PC-LB published until October 20, 2023. The primary outcome was diagnostic adequacy. Secondary outcomes were: the number of complete portal tracts (CPTs), longest sample length (LSL), total sample length (TSL), post-procedure pain scores, and adverse events (AEs), including overall AEs and AEs excluding minor post-procedure symptoms. We compared binary outcomes using risk ratios (RRs) and continuous outcomes using the mean difference (MD) or standardized mean difference (SMD), with 95%CIs.

Results: Four RCTs (258 patients) were included. The EUS-LB group presented lower post-procedure pain scores (SMD -0.58, 95%CI -0.95 to -0.22) than the PC-LB group. Both groups performed similarly in terms of diagnostic adequacy (RR 1.0, 95%CI 0.96 to 1.04), number of CPTs (MD 2.57, 95%CI -4.09 to 9.22), LSL (MD -2.91 mm, 95%CI -5.86 to 0.03), TSL (MD 4.16 mm, 95%CI -10.12 to 18.45), overall AEs (RR 0.54, 95%CI 0.20 to 1.46), and AEs excluding minor post-procedure symptoms (RR 1.65, 95%CI 0.21 to 13.02).

Conclusions: This meta-analysis suggests that EUS-LB is as safe and effective as PC-LB and is associated with lower post-procedure pain scores.Registration on PROSPERO: CRD42023469469.

PubMed Disclaimer

Conflict of interest statement

F. Maluf-Filho has served on the advisory boards of Boston Scientific, Olympus, Medtronic, and Cook in the past 3 years. P.A. do Espirito Santo, G.C. Meine, A.L. Nau, E.C. Barbosa, S. Baraldo, and L. Lenz declare that they have no conflict of interest.

MeSH terms

LinkOut - more resources