Comparative Study
. 2025 May:74:28-33.
doi: 10.1016/j.carrev.2024.08.007. Epub 2024 Aug 22.

Performance of balloon-expandable transcatheter bioprostheses in inoperable patients with pure aortic regurgitation of a native valve: The BE-PANTHEON international project

Affiliations
Comparative Study

Performance of balloon-expandable transcatheter bioprostheses in inoperable patients with pure aortic regurgitation of a native valve: The BE-PANTHEON international project

Enrico Poletti et al. Cardiovasc Revasc Med. 2025 May.

Abstract

Background: The off-label utilization of transcatheter heart valve (THV) devices for the treatment of inoperable or high-surgical risk patients with pure native aortic valve regurgitation (NAVR) has demonstrated suboptimal outcomes, both with self- and balloon-expandable (BE) devices. The aim of this study is to compare the use of different BE scaffolds in treating pure NAVR.

Methods: Consecutive patients with pure severe NAVR who were deemed to be at high-risk and were treated with last-generation BE-THVs among seventeen Centers in Europe and US. Technical and device success rates were the primary objectives.

Results: Between February 2018 and July 2023, among 144 patients, 41 (28 %) received a MyVal device and 103 (72 %) were treated with a Sapien THV. Patients treated with a MyVal THV had an extra-large annulus more frequently compared to the Sapien group (49%vs.20 %, p < 0.001). Technical and device success rates were 90 % and 81 %, respectively, p > 0.1. The rate of THV migration/embolization (MyVal 4.9%vs. Sapien 11 %, p = 0.4) and second valve needed (4.9%vs.7.8 %, p = 0.7) were numerically lower in the MyVal group, whereas the rate of at least moderate paravalvular leak (15%vs.7.8 %, p = 0.2) and permanent pacemaker implantation (25%vs.18 %, p = 0.16) were numerically higher in the Myval group.

Conclusions: Off-label use of BE devices for pure NAVR represents a potential alternative in high-risk patients in the absence of dedicated devices. However, BE in NAVR is associated with suboptimal outcomes. The availability of larger THV sizes may introduce transcatheter aortic valve replacement as an effective treatment for patients traditionally deemed unsuitable.

Non-standard abbreviations and acronyms: AR = aortic regurgitation, BE = balloon-expandable, NAVR = native aortic valve regurgitation, PM = pacemaker, TAVR = transcatheter aortic valve replacement, THV = transcatheter heart valve, TVEM = transcatheter valve embolization and migration, VARC-3 = Valve Academic Research Consortium 3.

Keywords: Balloon-expandable; MyVal; Pure aortic regurgitation; Sapien; TAVR; Transcatheter aortic valve replacement.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest AS has served as a consultant for Edwards Lifesciences and NeoChord Inc. AL has served on the advisory board for Medtronic, Abbott Vascular, Boston Scientific, Edwards Lifesciences, Shifamed, NeoChord Inc., V-dyne, and Philips. LT is proctor/consultant for Abbot, BSCI, Medtronic, Meril. The other authors did not report any conflict of interest.