Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2024 Aug 12;24(16):5213.
doi: 10.3390/s24165213.

Absolute and Relative Reliability of Spatiotemporal Gait Characteristics Extracted from an Inertial Measurement Unit among Senior Adults Using a Passive Hip Exoskeleton: A Test-Retest Study

Affiliations

Absolute and Relative Reliability of Spatiotemporal Gait Characteristics Extracted from an Inertial Measurement Unit among Senior Adults Using a Passive Hip Exoskeleton: A Test-Retest Study

Cristina-Ioana Pîrșcoveanu et al. Sensors (Basel). .

Abstract

Background: Seniors wearing a passive hip exoskeleton (Exo) show increased walking speed and step length but reduced cadence. We assessed the test-retest reliability of seniors' gait characteristics with Exo.

Methods: Twenty seniors walked with and without Exo (noExo) on a 10 m indoor track over two sessions separated by one week. Speed, step length, cadence and step time variability were extracted from one inertial measurement unit (IMU) placed over the L5 vertebra. Relative and absolute reliability were assessed using the intraclass correlation coefficient (ICC), standard error of measurement (SEM) and minimal detectable change (MDC).

Results: The relative reliability of speed, step length, cadence and step time variability ranged from "almost perfect to substantial" for Exo and noExo with ICC values between 0.75 and 0.87 and 0.60 and 0.92, respectively. The SEM and MDC values for speed, step length cadence and step time variability during Exo and noExo were <0.002 and <0.006 m/s, <0.002 and <0.005 m, <0.30 and <0.83 steps/min and <0.38 s and <1.06 s, respectively.

Conclusions: The high test-retest reliability of speed, step length and cadence estimated from IMU suggest a robust extraction of spatiotemporal gait characteristics during exoskeleton use. These findings indicate that IMUs can be used to assess the effects of wearing an exoskeleton on seniors, thus offering the possibility of conducting longitudinal studies.

Keywords: accelerometer; cadence; speed; step length; walking.

PubMed Disclaimer

Conflict of interest statement

The authors declare no conflicts of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.

Figures

Figure 1
Figure 1
(A)—Illustration of experimental design and (B)—vertical acceleration segmentation procedure used to collect and analyze the gait of senior adults, where acc is vertical acceleration, IC is foot initial contact, and W1 is walk forward.
Figure 2
Figure 2
Bland-Altman plots for (A,B) cadence, (C,D) step length and (E,F) speed and step time variability (G,H) where the left and right panels show the data for participants walking without wearing the exoskeleton (noExo) condition and walking while wearing the exoskeleton (Exo), respectively. The upper and lower limits are illustrated by dashed lines and the bias as a solid full line. Each participant is illustrated as an unique color within the graphs.

Similar articles

References

    1. Hartmann A., Murer K., de Bie R.A., de Bruin E.D. Reproducibility of spatio-temporal gait parameters under different conditions in older adults using a trunk tri-axial accelerometer system. Gait Amp. Posture. 2009;30:351–355. doi: 10.1016/j.gaitpost.2009.06.008. - DOI - PubMed
    1. Del Din S., Godfrey A., Rochester L. Validation of an Accelerometer to Quantify a Comprehensive Battery of Gait Characteristics in Healthy Older Adults and Parkinson’s Disease: Toward Clinical and at Home Use. JBHI. 2016;20:838–847. doi: 10.1109/JBHI.2015.2419317. - DOI - PubMed
    1. Micó-Amigo M.E., Bonci T., Paraschiv-Ionescu A., Ullrich M., Kirk C., Soltani A., Küderle A., Gazit E., Salis F., Alcock L. Assessing real-world gait with digital technology? Validation, insights and recommendations from the Mobilise-D consortium. J. Neuroeng Rehabil. 2023;20:1–26. doi: 10.1186/s12984-023-01198-5. - DOI - PMC - PubMed
    1. Weir J. Quantifying Test-Retest Reliability Using the Intraclass Correlation Coefficient and the SEM. J. Strength Cond. Res. 2005;19:231–240. - PubMed
    1. Koo T.K., Li M.Y. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J. Chiropr. Med. 2016;15:155–163. doi: 10.1016/j.jcm.2016.02.012. - DOI - PMC - PubMed

LinkOut - more resources