Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2024;12(8):567-573.
doi: 10.22038/ABJS.2024.72837.3611.

Preoperative Three-Dimensional Planning of Screw Length is not Reliable in Osteotomies of the Humerus and Forearm

Affiliations

Preoperative Three-Dimensional Planning of Screw Length is not Reliable in Osteotomies of the Humerus and Forearm

Martine Van Den Boogaard et al. Arch Bone Jt Surg. 2024.

Abstract

Objectives: Pediatric upper extremity fractures are seen frequently and sometimes lead to malunion. Three-dimensional (3D) surgery planning is an innovative addition to surgical treatment for the correction of post-traumatic arm deformities. The detailed planning in three dimensions allows for optimization of correction and provides planning of the exact osteotomies which include the advised material for correction and fixation. However, no literature is available on the precision of this computerized sizing of implants and screws. This study aimed to investigate the differences between 3D planned and surgically implanted screws in patients with a corrective osteotomy of the arm.

Methods: Planned and implanted screw lengths were evaluated in patients who underwent a 3D planned corrective osteotomy of the humerus or forearm using patient-specific 3D printed drill- and sawblade guides. Postoperative information on implanted hardware was compared to the original planned screw lengths mentioned in the 3D planned surgery reports.

Results: Of the 159 included screws in 17 patients, 45% differed >1 mm from the planned length (P<0.001). Aberrant screws in the radius and ulna were often longer, while those in the humerus were often shorter. Most aberrant screws were seen in the proximity of the elbow joint.

Conclusion: This study showed that 3D-planned screws in corrective osteotomies of the humerus and forearm differ significantly from screw lengths used during surgery. This illustrates that surgeons should be cautious when performing osteotomies with 3D techniques and predefined screw sizes.

Keywords: Osteotomy; Patient-specific planning; Screw length; Surgical guides; Three-dimensional.

PubMed Disclaimer

Conflict of interest statement

N/A

Figures

Figure 1
Figure 1
Example of 3D planning of a distal humeral correction osteotomy. From left to right: a screw hole drill guide, a sawblade guide and planned plate and screws

References

    1. Otsuka NY, Kasser JR. Supracondylar Fractures of the Humerus in Children. J Am Acad Orthop Surg. 1997;5(1):19–26. - PubMed
    1. Pogue DJ, Viegas SF, Patterson RM, et al. Effects of distal radius fracture malunion on wrist joint mechanics. J Hand Surg Am. 1990;15(5):721–7. - PubMed
    1. van Bergen CJA. Pediatric Fractures Are Challenging from Head to Toe. Children (Basel) 2022;9(5) - PMC - PubMed
    1. Bergman E, Lempesis V, Jehpsson L, Rosengren BE, Karlsson MK. Childhood Distal Forearm Fracture Incidence in Malmö, Sweden 1950 to 2016. J Wrist Surg. 2021;10(2):129–135. - PMC - PubMed
    1. Shenoy PM, Islam A, Puri R. Current Management of Paediatric Supracondylar Fractures of the Humerus. Cureus. 2020;12(5):e8137. - PMC - PubMed

LinkOut - more resources