Heavily Labeled Signal Probe for Electrogenerated Chemiluminescence Peptide-Based Biosensing of Matrix Metalloproteinase 2
- PMID: 39212080
- DOI: 10.1002/asia.202400743
Heavily Labeled Signal Probe for Electrogenerated Chemiluminescence Peptide-Based Biosensing of Matrix Metalloproteinase 2
Abstract
The field of electrogenerated chemiluminescence (ECL) biosensing has witnessed remarkable growth, emphasizing the need for precise detection of biomarkers. The synthesis approach of peptide-based signal probe with high recognition ability and high ECL efficiency is a significant issue in the ECL biosensing. Here, a heavily labeled signal probe was synthesized for ECL peptide-based biosensing tactic by using a new aldehyde bearing cyclometalated Ir(III) complex ([Ir(bt)2(bpy-CHO)PF6 (bt=2-phenylbenzothiazole, bpy-CHO=4'-methyl-[2,2'-bipyridine]-4-carbaldehyde, denoted as Ir1) as ECL signal reagent and streptavidin (SA) as carrier protein. One ECL peptide-based biosensing method was exemplified for the detection of matrix metalloproteinase 2 (MMP-2) by using Ir1 labeled SA (SA-Ir1) as heavily labeled signal probe and biotinylated peptide as molecular recognition substrate. MMP-2 was sensitively detected in the range from 5 to 100 ng/mL with a detection limit of 1.5 ng/mL. Importantly, two detection modes differing in the order of cleavage recognition by MMP-2 and signal transduction with SA-Ir1 were compared for the first time. First cleavage and second signal transduction were proposed to be beneficial to sensitive detection of target, which provides some ideas for biomarker diagnostics in disease screening at an early stage.
Keywords: Cyclometalated iridium(III) complex; ECL biosensing; MMP-2; Peptide; Streptavidin.
© 2024 Wiley-VCH GmbH.
Similar articles
-
Coordination-Based Site-Specific Labeling Strategy for Electrogenerated Chemiluminescence Biosensing of Matrix Metalloproteinase 2.Anal Chem. 2024 Dec 10;96(49):19504-19510. doi: 10.1021/acs.analchem.4c04078. Epub 2024 Nov 26. Anal Chem. 2024. PMID: 39592147
-
Electrogenerated Chemiluminescence Biosensor for Quantization of Matrix Metalloproteinase-3 in Serum via Target-Induced Cleavage of Oligopeptide.Biosensors (Basel). 2024 Apr 8;14(4):181. doi: 10.3390/bios14040181. Biosensors (Basel). 2024. PMID: 38667174 Free PMC article.
-
Simple and sensitive electrogenerated chemiluminescence peptide-based biosensor for detection of matrix metalloproteinase 2 released from living cells.Anal Bioanal Chem. 2016 Oct;408(25):7067-75. doi: 10.1007/s00216-016-9360-z. Epub 2016 Mar 3. Anal Bioanal Chem. 2016. PMID: 26939670
-
Electrogenerated Chemiluminescence Biosensing.Anal Chem. 2020 Jan 7;92(1):524-534. doi: 10.1021/acs.analchem.9b03425. Epub 2019 Dec 16. Anal Chem. 2020. PMID: 31789502 Review.
-
A review of electrogenerated chemiluminescent biosensors for assays in biological matrices.Bioanalysis. 2016 Oct;8(19):2071-89. doi: 10.4155/bio-2016-0178. Epub 2016 Sep 9. Bioanalysis. 2016. PMID: 27611228 Free PMC article. Review.
References
-
- S. He, X. Wang, G. Xiang, K. Lac, C. Wang, S. Wang, Z. Ding, Chem. Asian J. 2022, 17, e202200727.
-
- H. Qi, C. Zhang, Anal. Chem. 2020, 92, 524–534.
-
- V. Vanova, K. Mitrevska, V. Milosavljevic, D. Hynek, L. Richtera, V. Adam, Biosens. Bioelectron. 2021, 180, 113087.
-
- H. Qi, Q. Dang, M. Dong, H. Gao, M. Li, Rev. Anal. Chem. 2014, 33, 255–263.
-
- A. M. Yip, C. K. Lai, K. S. Yiu, K. K. Lo, Angew. Chem. Int Ed. Engl. 2022, 61, e202116078.
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Miscellaneous