Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2024 Sep 3;47(1):523.
doi: 10.1007/s10143-024-02758-6.

Efficacy, safety, and impact of fluorescein in frameless stereotactic needle biopsies - a case series

Affiliations

Efficacy, safety, and impact of fluorescein in frameless stereotactic needle biopsies - a case series

Marcos Dellaretti et al. Neurosurg Rev. .

Abstract

Stereotactic needle biopsy stands as a crucial method for diagnosing intracranial lesions unsuitable for surgical intervention. Nonetheless, the potential for sampling errors lead to innovative approaches to enhance diagnostic precision. This study contrasts the outcomes of patients undergoing fluorescein-assisted frameless stereotactic needle biopsy with those receiving traditional biopsies to evaluate the impact on diagnostic accuracy and safety. This study included patients with contrast-enhancing intracranial lesions, comprising a prospective group undergoing fluorescein-assisted biopsies and a retrospective group undergoing conventional biopsies at the same institution. We've collected data on demographics, procedural specifics, diagnostic outcomes, and postoperative events. A comparative analysis involved 43 patients who received fluorescein-assisted biopsies against 77 patients who underwent conventional biopsies. The average age was 60.5 years. The fluorescein group exhibited a 93% success rate in diagnosis, markedly higher than the 70.1% in the non-fluorescein group (OR = 5.67; 95%IC: 1.59-20.24; p < 0.01). The rate of complications was statistically similar across both cohorts. Despite its established value, stereotactic needle biopsy is susceptible to inaccuracies and complications. The application of fluorescence-based adjuncts like 5-ALA and fluorescein has been investigated to improve diagnostic fidelity and reduce risks. These technologies potentially minimize the necessity for multiple biopsies, decrease surgical duration, and provide immediate verification of tumor presence. Fluorescein-assisted stereotactic biopsy emerges as an effective, secure alternative to conventional methods.

Keywords: Biopsy; Fluorescence; Stereotatic techniques.

PubMed Disclaimer

References

    1. Lobato RD, Rivas JJ, Cabello A, Roger R (1982) Stereotactic biopsy of Brain lesions visualized with computed tomography. Stereotact Funct Neurosurg 45(4–5):426–430. https://doi.org/10.1159/000101637 - DOI
    1. Braga HM, Dellaretti MA, Faria MP, Almeida JCD, Nascimento LMD (2023) Accuracy comparison between Frameless Biopsy and Frame-based biopsy: a retrospective study of a Case Series. Arq Bras Neurocir Braz Neurosurg 42(03):e233–e238. https://doi.org/10.1055/s-0043-1775556 - DOI
    1. Parney IF, Berger MS (2012) Principles of brain tumor surgery. Handbook of clinical neurology, vol 104. Elsevier, pp 187–213. doi: https://doi.org/10.1016/B978-0-444-52138-5.00015-3
    1. Dellaretti M, Reyns N, Touzet G et al (2012) Stereotactic biopsy for Brainstem tumors: comparison of Transcerebellar with Transfrontal Approach. Stereotact Funct Neurosurg 90(2):79–83. https://doi.org/10.1159/000335502 - DOI - PubMed
    1. Jackson RJ, Fuller GN, Abi-Said D et al Limitations of stereotactic biopsy in the initial management of gliomas. Published online 2001.

LinkOut - more resources