Corneal Clarity and Tomographic Patterns in Pseudoexfoliation Syndrome: A Severity-Based Investigation
- PMID: 39231628
- DOI: 10.1097/ICL.0000000000001126
Corneal Clarity and Tomographic Patterns in Pseudoexfoliation Syndrome: A Severity-Based Investigation
Abstract
Purpose: The aim of the study was to investigate the corneal and anterior segment characteristics in pseudoexfoliation syndrome (PXS), depending on the severity of the disease.
Materials and methods: This cross-sectional study was conducted at a tertiary care hospital, in the ophthalmology department, in Turkey. Pseudoexfoliation syndrome group was classified into three groups. Pseudoexfoliative material on the part of the pupillary border was classified as group 1, on the entire pupillary border was classified as group 2, and pseudoexfoliative material on the entire pupillary border and iris surface was classified as group 3. The control group was composed of age and gender-matched individuals who had undergone a completely normal ophthalmologic examination. Scheimpflug tomography was performed to record tomographical data.
Results: The PXS groups 1, 2, and 3, along with the control group, consist of 29, 32, 33, and 42 participants, respectively. There was no significant difference in age-gender distribution between patients and the control group ( P >0.05). Group 3 showed significant differences in central corneal thickness compared with the control group ( P =0.001). In addition, anterior chamber angle was found to be significantly lower in group 3 than the control group ( P <0.001). In corneal densitometry (CD) values, significant increases compared with the control group were observed in groups 2 and 3 across all anterior annuli ( P <0.001). In group 1, significant increases observed in the anterior 6-10 mm and 10-12 mm annuli ( P <0.001). In the middle 6-10 mm annuluses, only group 3 showed a significant increase compared with the control group ( P <0.001). In the posterior 0-2, 2-6, and 6-10 mm annuli, significant increases compared with the control were observed only in groups 2 and 3 ( P =0.001, P =0.001, P <0.001, respectively).
Conclusions: Corneal densitometry values, even without an increase in intraocular pressure, have a tendency to increase in PXS depending on the severity of the disease. While minimal changes were observed in the middle layer, it was particularly noted that the effects of the disease were more prominent in the peripheral cornea.
Copyright © 2024 Contact Lens Association of Ophthalmologists.
Conflict of interest statement
The authors have no funding or conflicts of interest to disclose.
References
-
- Lindberg JG. Clinical investigations on depigmentation of the pupillary border and translucency of the iris in cases of senile cataract and in normal eyes in elderly persons. Acta Ophthalmol Suppl (1985) 1989;190:1–96.
-
- Ritland JS, Egge K, Lydersen S, et al. Exfoliative glaucoma and primary open-angle glaucoma: Associations with death causes and comorbidity. Acta Ophthalmol Scand 2004;82:401–404.
-
- Schlotzer-Schrehardt U, Naumann GO. Ocular and systemic pseudoexfoliation syndrome. Am J Ophthalmol 2006;141:921–937.
-
- Ritch R, Schlotzer-Schrehardt U. Exfoliation (pseudoexfoliation) syndrome: Toward a new understanding. Proceedings of the first international think tank. Acta Ophthalmol Scand 2001;79:213–217.
-
- Naumann GO, Schlotzer-Schrehardt U, Kuchle M. Pseudoexfoliation syndrome for the comprehensive ophthalmologist. Intraocular and systemic manifestations. Ophthalmology 1998;105:951–968.
MeSH terms
LinkOut - more resources
Full Text Sources