Cardiac positron emission tomography and other modalities for coronary artery disease assessment: A snapshot from the medicare data
- PMID: 39233112
- DOI: 10.1016/j.nuclcard.2024.102030
Cardiac positron emission tomography and other modalities for coronary artery disease assessment: A snapshot from the medicare data
Abstract
Background: Positron emission tomography (PET) is an important tool for assessing coronary artery disease (CAD), but its widespread utilization is limited due to various factors, including limited local champion availability. This study aims to compare the frequency of PET procedures and their interpreters with other common CAD assessment modalities.
Methods: Using Medicare data, we examined the number of cardiac PET procedures billed and compared them with single-photon emission computed tomography (SPECT), coronary computed tomography angiography (CCTA), stress magnetic resonance imaging (MRI), and stress echocardiography. Healthcare Common Procedure Coding System codes were used to identify procedures. We calculated the total number of PET myocardial perfusion imaging (MPI) procedures, the proportion of PET/CT and myocardial blood flow (MBF) assessments, and the median number of studies read per physician. We also analyzed the trends in the use of different CAD assessment modalities between 2018 and 2022. Descriptive statistics summarized the data.
Results: In 2022, Medicare billed for 212,106 PET MPI scans. SPECT was six times more frequent (1,343,519), whereas stress echocardiography (201,676) and CCTA (118,734) had similar or lower use. Stress MRI (3,932) was least used. Of the PET MPI scans, 46% were PET/CT, and 39% included MBF measurements. Cardiologists interpreted 86% of PET scans, with a median of 58 studies per reader; 23% interpreted ≤25 studies annually. SPECT had a median of 63 studies per reader, and CCTA, stress MRI, and stress echocardiography had medians of 27, 20, and 24, respectively. PET, CT, and MRI use increased from 2018 to 2022, whereas SPECT and stress echocardiography declined.
Conclusion: In the Medicare population, radionuclide perfusion imaging (SPECT and PET) remained the preferred method for assessment of CAD, with SPECT being the most frequently used modality and PET being the second most frequently used modality for this application. However, PET/CT and MBF are underutilized, limiting diagnostic and prognostic capabilities. Efforts to enhance education and awareness of PET's advantages and to address barriers to its wider adoption are essential to maximize its clinical benefits and improve patient outcomes.
Keywords: Myocardial Blood Flow; PET/CT; Positron Emission Tomography; Single Photon Emission Computed Tomography.
Copyright © 2024 American Society of Nuclear Cardiology. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Real-world evidence study on the impact of SPECT MPI, PET MPI, cCTA and stress echocardiography on downstream healthcare utilisation in patients with coronary artery disease in the US.BMC Cardiovasc Disord. 2024 Oct 9;24(1):543. doi: 10.1186/s12872-024-04225-y. BMC Cardiovasc Disord. 2024. PMID: 39379835 Free PMC article.
-
Characteristics and key differences between patient populations receiving imaging modalities for coronary artery disease diagnosis in the US.BMC Cardiovasc Disord. 2023 May 15;23(1):251. doi: 10.1186/s12872-023-03218-7. BMC Cardiovasc Disord. 2023. PMID: 37189049 Free PMC article.
-
Positron emission tomography for the assessment of myocardial viability: an evidence-based analysis.Ont Health Technol Assess Ser. 2010;10(16):1-80. Epub 2010 Jul 1. Ont Health Technol Assess Ser. 2010. PMID: 23074393 Free PMC article.
-
Economic and healthcare resource utilization assessments of PET imaging in Coronary Artery Disease diagnosis: a systematic review and discussion of opportunities for future economic evaluations.J Med Econ. 2024 Jan-Dec;27(1):715-729. doi: 10.1080/13696998.2024.2345507. Epub 2024 May 6. J Med Econ. 2024. PMID: 38650543
-
Diagnosis and Prognosis of Coronary Artery Disease with SPECT and PET.Curr Cardiol Rep. 2019 May 18;21(7):57. doi: 10.1007/s11886-019-1146-4. Curr Cardiol Rep. 2019. PMID: 31104158 Review.
Cited by
-
The REgistry of Flow and Perfusion Imaging for Artificial INtelligEnce with PET (REFINE PET): Rationale and Design.medRxiv [Preprint]. 2025 Jul 11:2025.07.10.25330435. doi: 10.1101/2025.07.10.25330435. medRxiv. 2025. Update in: J Nucl Cardiol. 2025 Aug 5:102449. doi: 10.1016/j.nuclcard.2025.102449. PMID: 40672503 Free PMC article. Updated. Preprint.
-
AI-based Hepatic Steatosis Detection and Integrated Hepatic Assessment from Cardiac CT Attenuation Scans Enhances All-cause Mortality Risk Stratification: A Multi-center Study.medRxiv [Preprint]. 2025 Jul 17:2025.06.09.25329157. doi: 10.1101/2025.06.09.25329157. medRxiv. 2025. PMID: 40585138 Free PMC article. Preprint.
-
Emerging Applications of Positron Emission Tomography in Coronary Artery Disease.J Pers Med. 2025 Mar 3;15(3):100. doi: 10.3390/jpm15030100. J Pers Med. 2025. PMID: 40137416 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous