Benefits, shortcomings, and costs of EEG monitoring
- PMID: 3923954
- PMCID: PMC1250821
- DOI: 10.1097/00000658-198506000-00017
Benefits, shortcomings, and costs of EEG monitoring
Abstract
A 5-year experience with 562 carotid endarterectomies, using electroencephalogram (EEG) monitoring and selective shunting, was reviewed. EEG changes occurred in 102 patients (18%). The frequency of EEG changes, as related to cerebral vascular symptoms, was as follows: transient ischemic attacks, seven per cent (19/259); completed strokes, 37% (36/98); vertebral basilar insufficiency, 24% (32/135); asymptomatic, 21% (15/71). Patients with contralateral carotid occlusion exhibited EEG changes in 37% (28/76) of operations. Fifteen patients suffered perioperative strokes (2.6%). Nine of the 15 were associated with a technical problem of either thrombosis of the internal carotid artery (five) or emboli (four). Technical problems were more common when shunts were used (five per cent) than when they were not (0.9%). Patients who suffered strokes prior to surgery were more at risk to develop a perioperative stroke (three per cent) than those not suffering prior strokes (0.3%). The EEG did not change in three patients who had lacunar infarcts prior to surgery and who awoke with a worsened deficit. Our series does not clearly establish the advantages of EEG monitoring, which is expensive (+375/patient) and may not detect ischemia in all areas of the brain. However, the use of shunts may introduce a risk of stroke due to technical error that is equal or greater than the risk of stroke due to hemodynamic ischemia. Since the need for protection is unpredictable by angiographic or clinical criteria, the benefit of EEG monitoring may be in reducing the incidence of shunting in those patients whose tracing remains normal after clamping. The decision to shunt, however, when there is electrical dysfunction after carotid clamping should be based not only on the EEG but also on the clinical signs and computed tomography (CT) scan. Our data does not show a net benefit in selective shunting unless the patient has sustained a stroke prior to surgery.
Similar articles
-
Correlation of carotid artery stump pressure and neurologic changes during 474 carotid endarterectomies performed in awake patients.J Vasc Surg. 2005 Oct;42(4):684-9. doi: 10.1016/j.jvs.2005.06.003. J Vasc Surg. 2005. PMID: 16242555
-
Carotid endarterectomy with routine electroencephalography and selective shunting: Influence of contralateral internal carotid artery occlusion and utility in prevention of perioperative strokes.J Vasc Surg. 2002 Jun;35(6):1114-22. doi: 10.1067/mva.2002.124376. J Vasc Surg. 2002. PMID: 12042721
-
Limitations of electroencephalographic monitoring in the detection of cerebral ischemia accompanying carotid endarterectomy.J Vasc Surg. 1991 Mar;13(3):439-43. doi: 10.1067/mva.1991.26500. J Vasc Surg. 1991. PMID: 1999866
-
Perioperative stroke. Part I: General surgery, carotid artery disease, and carotid endarterectomy.Can J Anaesth. 1991 Apr;38(3):347-73. doi: 10.1007/BF03007628. Can J Anaesth. 1991. PMID: 2036698 Review.
-
Perioperative stroke: the noncardiac surgery patient.Int Anesthesiol Clin. 1986 Winter;24(4):101-34. doi: 10.1097/00004311-198602440-00008. Int Anesthesiol Clin. 1986. PMID: 3539814 Review.
Cited by
-
Monitoring cerebral ischemia during carotid endarterectomy and stenting.J Biomed Res. 2017 Jan;31(1):11-6. doi: 10.7555/JBR.31.20150171. Epub 2016 Mar 3. J Biomed Res. 2017. PMID: 27231044 Free PMC article. Review.
-
The risk-benefit ratio of intraoperative shunting during carotid endarterectomy. Relevancy to operative and postoperative results and complications.Ann Surg. 1986 Feb;203(2):196-204. doi: 10.1097/00000658-198602000-00014. Ann Surg. 1986. PMID: 3947156 Free PMC article.
-
Utilizing EEG and fNIRS for the detection of sleep-deprivation-induced fatigue and its inhibition using colored light stimulation.Sci Rep. 2023 Apr 20;13(1):6465. doi: 10.1038/s41598-023-33426-2. Sci Rep. 2023. PMID: 37081056 Free PMC article.
-
Decoding of Pain Perception using EEG Signals for a Real-Time Reflex System in Prostheses: A Case Study.Sci Rep. 2020 Mar 27;10(1):5606. doi: 10.1038/s41598-020-62525-7. Sci Rep. 2020. PMID: 32221336 Free PMC article.
-
Genome-Wide Sequencing for Unexplained Developmental Disabilities or Multiple Congenital Anomalies: A Health Technology Assessment.Ont Health Technol Assess Ser. 2020 Mar 6;20(11):1-178. eCollection 2020. Ont Health Technol Assess Ser. 2020. PMID: 32194879 Free PMC article.
References
MeSH terms
LinkOut - more resources
Full Text Sources
Medical