Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2024 Sep 23;17(18):2113-2122.
doi: 10.1016/j.jcin.2024.05.036. Epub 2024 Sep 4.

Percutaneous Edge-to-Edge Repair for Tricuspid Regurgitation: 3-Year Outcomes From the TRILUMINATE Study

Affiliations
Free article
Clinical Trial

Percutaneous Edge-to-Edge Repair for Tricuspid Regurgitation: 3-Year Outcomes From the TRILUMINATE Study

Georg Nickenig et al. JACC Cardiovasc Interv. .
Free article

Abstract

Background: Tricuspid regurgitation (TR) is a common valve disease that has a significant impact on patients' quality of life.

Objectives: This study sought to report the final 3-year outcomes of tricuspid transcatheter edge-to-edge repair (T-TEER) with the TriClip (Abbott) implant from the TRILUMINATE (TRILUMINATE Study With Abbott Transcatheter Clip Repair System in Patients With Moderate or Greater TR) study for the treatment of severe symptomatic TR.

Methods: The TRILUMINATE study (N = 98 subjects) is an international, prospective, single-arm, multicenter study to investigate the safety and performance of T-TEER with the TriClip implant in patients with symptomatic moderate or greater TR. Echocardiographic assessments were performed at a core laboratory.

Results: At 3 years, TR was reduced to moderate or less in 79% of subjects, and a reduction of at least 1 grade was achieved in 92% of subjects. TR reduction achieved at 1 year was sustained through 3 years. Subjects also experienced an improvement in heart failure symptoms assessed by NYHA functional class and quality of life assessed by the Kansas City Cardiomyopathy Questionnaire at 3 years compared to baseline. The site-reported heart failure hospitalization rate decreased from 0.56 events/patient-year 1 year before device implantation to 0.14 events/patient-year 3 years after device implantation, representing a reduction of 75% (P < 0.0001).

Conclusions: In the longest follow-up to date of any T-TEER therapy, the TRILUMINATE study demonstrated that the TriClip procedure is both safe and effective, with sustained benefits at 3 years in subjects with symptomatic moderate or greater TR. (TRILUMINATE Study With Abbott Transcatheter Clip Repair System in Patients With Moderate or Greater TR [TRILUMINATE]; NCT03227757).

Keywords: TEER; TriClip; leaflet repair; tricuspid regurgitation; tricuspid repair.

PubMed Disclaimer

Conflict of interest statement

Funding Support and Author Disclosures This study was supported by Abbott Structural Heart. Dr Nickenig has received research funding and honoraria from Abbott, Edwards Lifesciences, and Medtronic; and has participated in clinical trials with Abbott, Edwards Lifesciences, and Medtronic. Dr Lurz has served as a consultant for Abbott Structural Heart, Edwards Lifesciences, Medtronic, ReCor, and Occlutech. Dr Sorajja has served as a consultant for 4C Medical, Abbott Structural, Adona, Boston Scientific, Edwards Lifesciences, Foldax, GE Medical, GLG, Medtronic, Phillips, Siemens, WL Gore, vDyne, and xDot; and has received personal fees from Abbott Vascular (outside the submitted work). Dr von Bardeleben has received institutional research grants and speaker honorarium from Abbott Vascular and Edwards Lifesciences; and has received nonfinancial trial support from Abbott Vascular, Boston Scientific, Edwards Lifesciences, Lifetec, and Medtronic. Dr Sitges has served as a consultant for Abbott, Edwards Lifesciences, Metronic, and General Electric; has received speaker honoraria from Abbott, Edwards Lifesciences, Medtronic, and General Electric; and has received speaker honoraria and travel and grant support from Abbott. Dr Hausleiter has received speaker honoraria and research support from Abbott Vascular and Edwards Lifesciences. Dr Trochu has received speaker honoraria, travel support, and grant support from Abbott and Novartis; has received honoraria for lectures or advisory boards from Amgen, Bayer, and Resmed; and has been an unpaid member of the Corvia Medical Scientific Advisory Group. Dr Näbauer has received speaker honoraria from Abbott. Dr Heitkemper is an employee of Abbott. Dr Hahn has received speaker fees from Abbott Structural, Baylis Medical, Edwards Lifesciences, and Philips Healthcare; and has institutional consulting contracts for which she receives no direct compensation with Abbott Structural, Boston Scientific, Edwards Lifesciences, Medtronic, and Novartis. All other authors have reported that they have no relationships relevant to the contents of this paper to disclose.

MeSH terms

Associated data

LinkOut - more resources