. 2024 Sep 18;16(37):49186-49196.
doi: 10.1021/acsami.4c12623. Epub 2024 Sep 10.

Synergistic Procoagulant Mechanism and Application of Kaolin-Zeolite Composite Hemostat for Effective Hemorrhage Control

Affiliations

Synergistic Procoagulant Mechanism and Application of Kaolin-Zeolite Composite Hemostat for Effective Hemorrhage Control

Chenchen Wang et al. ACS Appl Mater Interfaces. .

Abstract

Achieving timely and effective hemorrhage control is imperative for the survival of individuals with severe bleeding. Hemostatic materials, by enhancing the natural cell-based coagulation response, are essential tools in modern and military medical practice for controlling bleeding, especially in emergency and surgical settings. Here, we report a new type of composite hemostatic material with two different aluminosilicate-based components, kaolin and zeolite, which synergistically work together in different stages of the coagulation cascade reactions. Kaolin can effectively activate the clotting factor FXII in the early stage, and zeolite can accumulate and assemble FXa and FVa on its surface and thereafter lead to the formation of highly active thrombin in the later stage. The synergistic action mechanism between kaolin and zeolite significantly boosts the levels of FXIIa and FXa, and it also greatly enhances plateau thrombin activity. For practical application, a kaolin-modified zeolite gauze is fabricated, and it demonstrates excellent hemostatic effectiveness. Compared to the combat gauze currently used in front-line treatment, it reduces blood loss by 75% and shortens hemostasis time by 33% in a rabbit femoral artery injury model. In addition, this kaolin-zeolite gauze has no heat release problem and a nearly zero particle shedding rate, which greatly decreases the safety risk compared to current commercial inorganic-based hemostatic gauzes.

Keywords: blood coagulation factor; composite hemostatic gauze; hemostasis; kaolin; synergistic effect; zeolite.