Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2024 Dec:69:152545.
doi: 10.1016/j.semarthrit.2024.152545. Epub 2024 Sep 1.

Validation of the ankle-specific pediatric arthritis ultrasound scoring system in children with juvenile idiopathic arthritis

Affiliations
Free article

Validation of the ankle-specific pediatric arthritis ultrasound scoring system in children with juvenile idiopathic arthritis

Patricia Vega-Fernandez et al. Semin Arthritis Rheum. 2024 Dec.
Free article

Abstract

Objective: To validate the ankle-specific Pediatric Arthritis Ultrasound Scoring System (PAUSS-ankle) in children with juvenile idiopathic arthritis (JIA).

Methods: Patients with a diagnosis of JIA prospectively underwent a standard clinical assessment and musculoskeletal ultrasound (MSUS) of one or both ankles. B-mode and Power-Doppler mode MSUS images were acquired and scored according to the PAUSS-ankle protocol. A subset of patients received a contrast-enhanced MRI (ceMRI) of the affected ankle. ceMRI scoring for synovitis was performed according to the Rheumatoid Arthritis MRI System (RAMRIS). Test characteristics of the PAUSS-ankle scores were evaluated with ceMRI as reference. Associations between the findings on physical examination, PAUSS-ankle, and RAMRIS were investigated.

Results: Thirty-two patients with JIA contributed 63 MSUS and 15 ceMRIs of the ankles. The PAUSS-ankle total B-mode score had a moderate correlation with physical examination findings (correlation (r)=0.43, p < 0.001). The PAUSS-ankle B-mode score ≥1 exhibited a sensitivity of 79 % and specificity of 100 %, demonstrating excellent diagnostic accuracy with an area under the curve (AUC)= 0.89 (confidence intervals, CI, 0.78-1.00) while clinical assessment had a sensitivity of 57 % and AUC= 0.71 (CI: 0.58-0.85). The PAUSS-ankle B-mode score had significant strong correlations (r = 0.68-0.90, p < 0.005) with the RAMRIS for the assessment of disease severity for each joint area and the ankle joint as a whole.

Conclusion: Our findings demonstrate excellent diagnostic accuracy of the PAUSS-ankle in detecting the presence and severity of ankle synovitis when compared to ceMRI. The PAUSS-ankle holds significant promise as an accurate measurement that may complement current clinical standards.

Keywords: Ankle; Diagnostic imaging; Juvenile idiopathic arthritis; Musculoskeletal ultrasound.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest The authors have no conflicts of interest to declare related to this publication. All co-authors have seen and agree with the contents of the manuscript and there is no financial interest to report.

References

Publication types

LinkOut - more resources