Comparison of health problems related to work and environmental measurements in two office buildings with different ventilation systems
- PMID: 3926199
- PMCID: PMC1416460
- DOI: 10.1136/bmj.291.6492.373
Comparison of health problems related to work and environmental measurements in two office buildings with different ventilation systems
Abstract
A cross sectional survey investigating "building sickness" was carried out in two buildings with similar populations of office workers but differing ventilation systems, one being fully air conditioned with humidification and the other naturally ventilated. The prevalence of symptoms related to work was assessed by a questionnaire administered by a doctor. A stratified, randomly selected sample of workers was seen (84% response). Building sickness includes several distinct syndromes related to work, most of which were significantly more common in the air conditioned building than the naturally ventilated building--namely, rhinitis (28% v 5%), nasal blockage and dry throat (35% v 9%), lethargy (36% v 13%), and headache (31% v 15%). The prevalence of work related asthma and humidifier fever was low and did not differ significantly between the two buildings. An environmental assessment of the offices was performed to attempt to identify possible factors responsible for the differences in the prevalence of disease. Globe temperature, dry bulb temperature, relative humidity, moisture content, air velocity, positive and negative ions, and carbon monoxide, ozone, and formaldehyde concentrations were all measured. None of these factors differed between the buildings, suggesting that building sickness is caused by other factors.
Similar articles
-
The sick building syndrome: prevalence studies.Br Med J (Clin Res Ed). 1984 Dec 8;289(6458):1573-5. doi: 10.1136/bmj.289.6458.1573. Br Med J (Clin Res Ed). 1984. PMID: 6439323 Free PMC article.
-
Influence of indoor air quality and personal factors on the sick building syndrome (SBS) in Swedish geriatric hospitals.Occup Environ Med. 1995 Mar;52(3):170-6. doi: 10.1136/oem.52.3.170. Occup Environ Med. 1995. PMID: 7735389 Free PMC article.
-
Symptoms prevalence among office workers of a sealed versus a non-sealed building: associations to indoor air quality.Environ Int. 2009 Nov;35(8):1136-41. doi: 10.1016/j.envint.2009.07.005. Epub 2009 Aug 8. Environ Int. 2009. PMID: 19665795
-
Summary of human responses to ventilation.Indoor Air. 2004;14 Suppl 7:102-18. doi: 10.1111/j.1600-0668.2004.00279.x. Indoor Air. 2004. PMID: 15330778 Review.
-
Human health and air conditioning systems.G Ital Med Lav. 1991 Jan-Nov;13(1-6):51-4. G Ital Med Lav. 1991. PMID: 1845458 Review.
Cited by
-
Exposure to varying levels of contaminants and symptoms among workers in two office buildings.Am J Public Health. 1996 Nov;86(11):1629-33. doi: 10.2105/ajph.86.11.1629. Am J Public Health. 1996. PMID: 8916534 Free PMC article. Clinical Trial.
-
Headaches in civil servants: effect on work and leisure.Br J Ind Med. 1988 May;45(5):336-40. doi: 10.1136/oem.45.5.336. Br J Ind Med. 1988. PMID: 3378014 Free PMC article.
-
Sick-building syndrome fatigue as a possible predation defense.Integr Physiol Behav Sci. 1995 Jan-Mar;30(1):68-83. doi: 10.1007/BF02691390. Integr Physiol Behav Sci. 1995. PMID: 7794787 Review.
-
Workplace lighting for improving alertness and mood in daytime workers.Cochrane Database Syst Rev. 2018 Mar 2;3(3):CD012243. doi: 10.1002/14651858.CD012243.pub2. Cochrane Database Syst Rev. 2018. PMID: 29498416 Free PMC article.
-
Sick building syndrome.Occup Environ Med. 2004 Feb;61(2):185-90. doi: 10.1136/oem.2003.008813. Occup Environ Med. 2004. PMID: 14739390 Free PMC article. Review. No abstract available.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical