Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2024 Sep 16;17(3):285-296.

A randomised controlled trial comparing the effectiveness of guided bone regeneration with polytetrafluoroethylene titanium-reinforced membranes, CAD/CAM semi-occlusive titanium meshes and CAD/CAM occlusive titanium foils in partially atrophic arches

  • PMID: 39283222
Randomized Controlled Trial

A randomised controlled trial comparing the effectiveness of guided bone regeneration with polytetrafluoroethylene titanium-reinforced membranes, CAD/CAM semi-occlusive titanium meshes and CAD/CAM occlusive titanium foils in partially atrophic arches

Pietro Felice et al. Int J Oral Implantol (Berl). .

Abstract

Purpose: To compare the clinical effectiveness of three different devices used in guided bone regeneration procedures for partially atrophic arches.

Materials and methods: A randomised controlled trial with three parallel arms was conducted. The study evaluated titanium-reinforced polytetrafluoroethylene membrane (PTFE group), semi-occlusive CAD/CAM titanium mesh (mesh group) and occlusive CAD/CAM titanium foil (foil group) in terms of surgical outcomes and complications as well as surgical times and surgeon satisfaction in 27 guided bone regeneration procedures, presenting results from 1 year post-implant placement.

Results: Complications occurred in seven patients. No significant difference was found between the groups in terms of the occurrence of complications (P = 0.51), device exposure (P = 0.12) and implant failure (P = 0.650). Surgeon satisfaction varied significantly, with the PTFE group differing from the mesh (P = 0.003) and foil groups (P 0.001), but not between meshes and foils (P = 0.172). Surgical times also differed significantly, with longer times for PTFE membranes compared to meshes (P 0.001) and foils (P = 0.006), but with no difference between meshes and foils (P = 0.308). The mean reconstructed bone volume was 1269.55 ± 561.08 mm3, with no significant difference observed between the three groups (P = 0.815). There was also no significant difference for mean maximum height (6.72 mm, P = 0.867) and width (7.69 mm, P = 0.998). The mean marginal bone loss at 1 year after implant placement was 0.59 ± 0.27 mm.

Conclusions: Although this study provides valuable insights into the potential benefits of using different types of CAD/CAM devices, further research with larger sample sizes and longer follow-up periods is warranted to validate these findings.

Conflict-of-interest statement: The authors declare there are no conflicts of interest relating to this study.

Keywords: CAD/CAM; dental implants; foil; guided bone regeneration; mesh.

PubMed Disclaimer

References

Publication types

LinkOut - more resources