Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2025 Jan 15:325:125153.
doi: 10.1016/j.saa.2024.125153. Epub 2024 Sep 18.

Improving monitoring of dissolved organic matter from the wastewater treatment plant to the receiving environment: A new high-frequency in situ fluorescence sensor capable of analyzing 29 pairs of Ex/Em wavelengths

Affiliations

Improving monitoring of dissolved organic matter from the wastewater treatment plant to the receiving environment: A new high-frequency in situ fluorescence sensor capable of analyzing 29 pairs of Ex/Em wavelengths

Angélique Goffin et al. Spectrochim Acta A Mol Biomol Spectrosc. .

Abstract

A high-frequency, in situ fluorescence probe, called Fluocopée®, has been developed in order to better monitor variations in both the quality and quantity of dissolved organic matter within various aquatic environments (e.g. wastewater, receiving environments) thanks to a wide choice of 29 measured Excitation/Emission wavelength pairs. This advance pave the way to new measurement possibilities in comparison with existing probes, which are usually only able to measure 1-4 fluorophores. The qualification tests of the Fluocopée® probe indicate a high level of accuracy for the measurements of tyrosine, tryptophan and humic acids solutions. Good repeatability and reproducibility are also observed. For the first time, this tool has been deployed in an urban watershed (Bougival, Seine River, downstream of Paris) and in the settled effluent from a wastewater treatment plant (Seine aval, Achères, France). This new high-frequency in situ probe offers great application potential, including organic matter quality and quantity monitoring at drinking and wastewater treatment plants (treatment optimization) and in continental and marine waters (the fate of organic matter in biogeochemical cycles).

Keywords: Fluorescence spectroscopy; High frequency; In situ sensors; Organic matter; Receiving environments; Wastewater.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

LinkOut - more resources