Flexible PZT-Based Row-Column Addressed 2-D PMUT Array
- PMID: 39312430
- DOI: 10.1109/TUFFC.2024.3465589
Flexible PZT-Based Row-Column Addressed 2-D PMUT Array
Abstract
This article reports a row-column (RC) addressed flexible piezoelectric micromachined ultrasound transducer (PMUT) array with a top-down fabrication process. The fabrication uses a temporary carrier wafer from which the array device is released by deep reactive ion etching (DRIE). About 0.8- m-thick sol-gel processed lead zirconate titanate (PZT) thin film acts as the active piezoelectric. The flexible PMUT membrane includes the PZT film and a 14- m polyimide as a passive layer. A sidewall made of polyimide measuring m in thickness with a cavity of m in diameter is realized by reactive ion etching (RIE). Laser Doppler vibrometer (LDV) characterization of the PMUT indicates 2.7 and 2.1 MHz as the resonance frequency in-air and underwater, respectively. Excitation of a single PMUT element coupled with 5-V direct current (dc) bias results in 1.2-nm/V sensitivity in-air, whereas when the same is excited along with 10-V dc bias, a pressure response of 40 Pa/V at 1 cm is measured underwater using a hydrophone. The presented results under bending to an 8-mm bending radius show the potential for wearable applications in shallow-depth regions subject to further optimization.
Similar articles
-
Polyimide-On-Silicon 2D Piezoelectric Micromachined Ultrasound Transducer (PMUT) Array.Sensors (Basel). 2023 May 17;23(10):4826. doi: 10.3390/s23104826. Sensors (Basel). 2023. PMID: 37430741 Free PMC article.
-
Flexible Thin-Film PZT Ultrasonic Transducers on Polyimide Substrates.Sensors (Basel). 2021 Feb 2;21(3):1014. doi: 10.3390/s21031014. Sensors (Basel). 2021. PMID: 33540796 Free PMC article.
-
10 MHz Thin-Film PZT-Based Flexible PMUT Array: Finite Element Design and Characterization.Sensors (Basel). 2020 Aug 4;20(15):4335. doi: 10.3390/s20154335. Sensors (Basel). 2020. PMID: 32759665 Free PMC article.
-
Piezoelectric Micromachined Ultrasound Transducer Technology: Recent Advances and Applications.Biosensors (Basel). 2022 Dec 29;13(1):55. doi: 10.3390/bios13010055. Biosensors (Basel). 2022. PMID: 36671890 Free PMC article. Review.
-
Review of pMUTs for medical imaging: towards high frequency arrays.Biomed Phys Eng Express. 2023 Jan 12;9(2). doi: 10.1088/2057-1976/acaab2. Biomed Phys Eng Express. 2023. PMID: 36595267 Review.
Cited by
-
Flexible micromachined ultrasound transducers (MUTs) for biomedical applications.Microsyst Nanoeng. 2025 Jan 16;11(1):9. doi: 10.1038/s41378-024-00783-5. Microsyst Nanoeng. 2025. PMID: 39814707 Free PMC article. Review.
LinkOut - more resources
Full Text Sources