Development of a µPAD for the point-of-care testing of serum glutamic oxaloacetic transaminase (SGOT)
- PMID: 39320528
- DOI: 10.1007/s00604-024-06678-6
Development of a µPAD for the point-of-care testing of serum glutamic oxaloacetic transaminase (SGOT)
Abstract
A wax-patterned paper analytical device (µPAD) has been developed for point-of-care colourimetric testing of serum glutamic oxaloacetic transaminase (SGOT). The detection method was based on the transamination reaction of aspartate with α-ketoglutarate, leading to the formation of oxaloacetate which reacts with the reagent Fast Blue BB salt and forms a cavern pink colour. The intensity of the cavern pink colour grows as the concentration of SGOT increases. UV-visible spectroscopy was utilized to optimize reaction conditions, and the optimized reagents were dropped onto the wax-patterned paper. The coloured PADs, after the addition of SGOT, have been photographed, and a colour band has been generated to correlate the SGOT concentration visually. The images were used to calculate the intensity values using ImageJ software, which inturn was used to calculate the SGOT concentration. The PADs were also tested with serum samples, and SGOT spiked serum samples. The PAD could detect the SGOT concentration ranging from 5 to 200 U/L. The analysis yielded highly accurate results with less than 6% relative error compared to the clinical sample. This colourimetric test demonstrated exceptional selectivity in the presence of other biomolecules in the blood serum, with a detection limit of 2.77 U/L and a limit of quantification of 9.25 U/L. Additionally, a plasma separation membrane was integrated with the PAD to directly test SGOT from finger-prick blood samples.
Keywords: Colourimetric detection; Fast Blue BB salt; ImageJ software; Liver function biomarker; Paper analytical devices; Point-of-care testing; RGB values; Serum glutamic oxaloacetic transaminase.
© 2024. The Author(s), under exclusive licence to Springer-Verlag GmbH Austria, part of Springer Nature.
Similar articles
-
A paper-based point-of-care testing device for the colourimetric estimation of bilirubin in blood sample.Spectrochim Acta A Mol Biomol Spectrosc. 2023 Feb 15;287(Pt 1):122045. doi: 10.1016/j.saa.2022.122045. Epub 2022 Oct 27. Spectrochim Acta A Mol Biomol Spectrosc. 2023. PMID: 36327811
-
Development of a paper-based analytical device for the colourimetric detection of alanine transaminase and the application of deep learning for image analysis.Anal Chim Acta. 2021 Dec 15;1188:339158. doi: 10.1016/j.aca.2021.339158. Epub 2021 Oct 14. Anal Chim Acta. 2021. PMID: 34794561
-
The role of elevated liver transaminase levels in children with blunt abdominal trauma.Injury. 2003 May;34(4):249-52. doi: 10.1016/s0020-1383(02)00188-2. Injury. 2003. PMID: 12667774
-
Analysis of serum glutamic pyruvic transaminase and serum glutamic oxaloacetic transaminase levels in tuberculosis patients who are undergoing oat treatment in Kendari City General Hospital, Kota Kendari, Indonesia.Infect Dis Rep. 2020 Jul 6;12(Suppl 1):8737. doi: 10.4081/idr.2020.8737. eCollection 2020 Jul 7. Infect Dis Rep. 2020. PMID: 32874466 Free PMC article.
-
Autoanalytic (colormetric) determinations of SGOT in isoniazid recipients are reliable.Am Rev Respir Dis. 1975 Feb;111(2):237-8. doi: 10.1164/arrd.1975.111.2.237. Am Rev Respir Dis. 1975. PMID: 1111405
Cited by
-
Copper and nickel doped carbon dots for rapid and sensitive fluorescent turn-off detection of bilirubin.Sci Rep. 2025 Jan 8;15(1):1262. doi: 10.1038/s41598-025-85246-1. Sci Rep. 2025. PMID: 39779895 Free PMC article.
References
-
- Asrani SK, Devarbhavi H, Eaton J, Kamath PS (2019) Burden of liver diseases in the world. J Hepatol 70:151–171. https://doi.org/10.1016/j.jhep.2018.09.014 - DOI - PubMed
-
- Vroon DH, Israili Z (1990) Alkaline phosphatase and gamma glutamyltransferase, The history, physical, and laboratory examinations. 3rd ed. Chapter 100, pp 492-493
-
- Osna N (2009) Alcohol and liver disease. Semin Liver Dis 29:139. https://doi.org/10.1055/s-0029-1214369 - DOI - PubMed
-
- Huang XJ, Choi YK, Im HS et al (2006) Aspartate aminotransferase (AST/GOT) and alanine aminotransferase (ALT/GPT) detection techniques. Sensors 6:756–782. https://doi.org/10.3390/s6070756 - DOI - PMC
-
- Karmen BA, Wroblewski F, Ladue JS (1954) Amino nitrogen. J Clin Invest, 34(1): 126–133
Publication types
MeSH terms
Substances
Grants and funding
- Sanction no. 102/IFD/SAN/2238/2016-17 dated 30/8/2016, and 102/IFD/SAN/1555/2018-2019 dated 13/6/2018./Department of Biotechnology (DBT), India
- Sanction no. 102/IFD/SAN/2238/2016-17 dated 30/8/2016, and 102/IFD/SAN/1555/2018-2019 dated 13/6/2018./Department of Biotechnology (DBT), India