Turbidimetry of rheumatoid factor in serum with a centrifugal analyzer
- PMID: 3940692
Turbidimetry of rheumatoid factor in serum with a centrifugal analyzer
Abstract
We describe the simple, rapid turbidimetry of IgM rheumatoid factor in human serum by use of the Cobas-Bio centrifugal analyzer. Heat-aggregated human IgG is used as the antigen. The immunoturbidimetric reaction is monitored at 340 nm for 300 s, and the changes in absorbance after the antigen is added are used to prepare the standard curve. Test results are calculated from the stored curve and reported in int. units/mL, based on comparison with the WHO reference serum for rheumatoid factor. There is no interference from bilirubin (up to 340 mumol/L) or hemoglobin (up to 5600 mg/L). Serum samples with a triglyceride concentration greater than 2.20 mmol/L must be cleared of lipids before analysis. The standard curve is linear from 30 to 500 int. units/mL. Precision, accuracy, linearity, and sensitivity are quite acceptable. The CV was generally less than 5% for different concentrations of rheumatoid factor. Results agree well with those by a rate-nephelometric procedure on the Beckman ICS system (rs = 0.932). However, both correlate poorly with a modified classical Waaler-Rose test. Of 47 patients with rheumatoid arthritis, 34 had IgM rheumatoid factor in their serum, but the measured value did not reflect the activity of the disease.
Similar articles
-
Rate nephelometric measurement of rheumatoid factor in serum.Clin Chem. 1979 Nov;25(11):1909-14. Clin Chem. 1979. PMID: 498500
-
Immunochemical determination of human immunoglobulins: use of kinetic turbidimetry and a 36-place centrifugal analyzer.Clin Chem. 1979 Apr;25(4):526-30. Clin Chem. 1979. PMID: 466760
-
Clinical value of ELISA assays for IgM and IgG rheumatoid factors.J Clin Pathol. 1987 Jan;40(1):107-11. doi: 10.1136/jcp.40.1.107. J Clin Pathol. 1987. PMID: 3818968 Free PMC article.
-
[Rheumatoid factors].Rev Rhum Mal Osteoartic. 1984 Apr;51(4):219-27. Rev Rhum Mal Osteoartic. 1984. PMID: 6203165 Review. French. No abstract available.
-
The use of a centrifugal fast analyzer for biochemical and immunological analysis.Methods Biochem Anal. 1976;23(0):189-248. doi: 10.1002/9780470110430.ch3. Methods Biochem Anal. 1976. PMID: 794627 Review. No abstract available.
Cited by
-
Comparison of Serological Biomarkers in Rheumatoid Arthritis and Their Combination to Improve Diagnostic Performance.Front Immunol. 2018 Jun 6;9:1113. doi: 10.3389/fimmu.2018.01113. eCollection 2018. Front Immunol. 2018. PMID: 29928272 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Other Literature Sources