Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2025 Mar;18(1):47-57.
doi: 10.1007/s12194-024-00853-3. Epub 2024 Oct 23.

Deep learning-based approach for acquisition time reduction in ventilation SPECT in patients after lung transplantation

Affiliations

Deep learning-based approach for acquisition time reduction in ventilation SPECT in patients after lung transplantation

Masahiro Nakashima et al. Radiol Phys Technol. 2025 Mar.

Abstract

We aimed to evaluate the image quality and diagnostic performance of chronic lung allograft dysfunction (CLAD) with lung ventilation single-photon emission computed tomography (SPECT) images acquired briefly using a convolutional neural network (CNN) in patients after lung transplantation and to explore the feasibility of short acquisition times. We retrospectively identified 93 consecutive lung-transplant recipients who underwent ventilation SPECT/computed tomography (CT). We employed a CNN to distinguish the images acquired in full time from those acquired in a short time. The image quality was evaluated using the structural similarity index (SSIM) loss and normalized mean square error (NMSE). The correlation between functional volume/morphological volume (F/M) ratios of full-time SPECT images and predicted SPECT images was evaluated. Differences in the F/M ratio were evaluated using Bland-Altman plots, and the diagnostic performance was compared using the area under the curve (AUC). The learning curve, obtained using MSE, converged within 100 epochs. The NMSE was significantly lower (P < 0.001) and the SSIM was significantly higher (P < 0.001) for the CNN-predicted SPECT images compared to the short-time SPECT images. The F/M ratio of full-time SPECT images and predicted SPECT images showed a significant correlation (r = 0.955, P < 0.0001). The Bland-Altman plot revealed a bias of -7.90% in the F/M ratio. The AUC values were 0.942 for full-time SPECT images, 0.934 for predicted SPECT images and 0.872 for short-time SPECT images. Our findings suggest that a deep-learning-based approach can significantly curtail the acquisition time of ventilation SPECT, while preserving the image quality and diagnostic accuracy for CLAD.

Keywords: Chronic lung allograft dysfunction; Convolutional neural network; Deep learning; Lung transplantation; Single photon emission computed tomography.

PubMed Disclaimer

Conflict of interest statement

Declarations. Conflict of interest: The authors have no competing interests to declare that are relevant to the content of this article. Ethical approval: All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards. The study was approved by the Bioethics Committee of the Okayama University Hospital (KEN2401-020).

References

    1. Bajc M, Schümichen C, Grüning T, et al. EANM guideline for ventilation/perfusion single-photon emission computed tomography (SPECT) for diagnosis of pulmonary embolism and beyond. Eur J Nucl Med Mol Imaging. 2019;46:2429–51. - DOI - PubMed - PMC
    1. LaFrance N, Fournier F. Radioaerosols and the updated EANM guideline in ventilation/perfusion imaging. Eur J Nucl Med Mol Imaging. 2020;47:1640–2. - DOI - PubMed - PMC
    1. Evbuomwan O, Endres W, Tebeila T, Engelbrecht G. Identification and follow-up of COVID-19 related matching ventilation and perfusion defects on functional imaging using VQ SPECT/CT. Nucl Med Mol Imaging. 2023;57:9–15. - DOI - PubMed
    1. Xie H, Zhao Z, Zhang W, Li L. Quantitative analysis of lung function and airway remodeling using ventilation/perfusion single photon emission tomography/computed tomography and HRCT in patients with chronic obstructive pulmonary disease and asthma. Ann Nucl Med. 2023;37:504–16. - DOI - PubMed
    1. Nakashima M, Shinya T, Oto T, Okawa T, Takeda Y. Diagnostic value of ventilation/perfusion single-photon emission computed tomography/computed tomography for bronchiolitis obliterans syndrome in patients after lung transplantation. Nucl Med Commun. 2019;40:703–10. - DOI - PubMed

LinkOut - more resources