Customized 3D-Printed Mesh, Membrane, Bone Substitute, and Dental Implant Applied to Guided Bone Regeneration in Oral Implantology: A Narrative Review
- PMID: 39452431
- PMCID: PMC11506345
- DOI: 10.3390/dj12100303
Customized 3D-Printed Mesh, Membrane, Bone Substitute, and Dental Implant Applied to Guided Bone Regeneration in Oral Implantology: A Narrative Review
Abstract
Background: The new frontiers of computer-based surgery, technology, and material advances, have allowed for customized 3D printed manufacturing to become widespread in guided bone regeneration (GBR) in oral implantology. The shape, structural, mechanical, and biological manufacturing characteristics achieved through 3D printing technologies allow for the customization of implant-prosthetic rehabilitations and GBR procedures according to patient-specific needs, reducing complications and surgery time. Therefore, the present narrative review aims to elucidate the 3D-printing digital radiographic process, materials, indications, 3D printed manufacturing-controlled characteristics, histological findings, complications, patient-reported outcomes, and short- and long-term clinical considerations of customized 3D printed mesh, membranes, bone substitutes, and dental implants applied to GBR in oral implantology. Methods: An electronic search was performed through MEDLINE/PubMed, Scopus, BioMed Central, and Web of Science until 30 June 2024. Results: Three-dimensionally printed titanium meshes and bone substitutes registered successful outcomes in vertical/horizontal bone defect regeneration. Three-dimensionally printed polymeric membranes could link the advantages of conventional resorbable and non-resorbable membranes. Few data on customized 3D printed dental implants and abutments are available, but in vitro and animal studies have shown new promising designs that could improve their mechanical properties and tribocorrosion-associated complications. Conclusions: While 3D printing technology has demonstrated potential in GBR, additional human studies are needed to evaluate the short- and long-term follow-up of peri-implant bone levels and volumes following prosthetic functional loading.
Keywords: 3D printing; GBR; abutment; bone substitutes; dentistry; guided bone regeneration; implant; implantology; membrane; mesh; oral.
Conflict of interest statement
The authors declare no conflicts of interest.
Figures


Similar articles
-
Research on the dimensional accuracy of customized bone augmentation combined with 3D-printing individualized titanium mesh: A retrospective case series study.Clin Implant Dent Relat Res. 2021 Feb;23(1):5-18. doi: 10.1111/cid.12966. Epub 2020 Dec 17. Clin Implant Dent Relat Res. 2021. PMID: 33336492
-
Customized 3D-Printed Titanium Mesh Developed for an Aesthetic Zone to Regenerate a Complex Bone Defect Resulting after a Deficient Odontectomy: A Case Report.Medicina (Kaunas). 2022 Sep 1;58(9):1192. doi: 10.3390/medicina58091192. Medicina (Kaunas). 2022. PMID: 36143869 Free PMC article.
-
Current applications of 3D printing in dental implantology: A scoping review mapping the evidence.Clin Oral Implants Res. 2024 Aug;35(8):1011-1032. doi: 10.1111/clr.14198. Epub 2023 Nov 6. Clin Oral Implants Res. 2024. PMID: 37929684
-
Digital Workflow with Open-Source CAD-CAM Software Aimed to Design a Customized 3D Laser-Printed Titanium Mesh for Guided Bone Regeneration.Bioengineering (Basel). 2025 Apr 22;12(5):436. doi: 10.3390/bioengineering12050436. Bioengineering (Basel). 2025. PMID: 40428055 Free PMC article.
-
Evaluation of efficacy of non-resorbable membranes compared to resorbable membranes in patients undergoing guided bone regeneration.Heliyon. 2023 Feb 4;9(3):e13488. doi: 10.1016/j.heliyon.2023.e13488. eCollection 2023 Mar. Heliyon. 2023. PMID: 36942236 Free PMC article. Review.
Cited by
-
Effect of different titanium mesh thicknesses on mechanical strength and bone stress: a finite element study.BMC Oral Health. 2025 Aug 20;25(1):1341. doi: 10.1186/s12903-025-06704-w. BMC Oral Health. 2025. PMID: 40835922 Free PMC article.
-
Customized Titanium Plates for Preventing Mandibular Fractures in Lower Third Molar Extractions.J Funct Biomater. 2025 Feb 13;16(2):64. doi: 10.3390/jfb16020064. J Funct Biomater. 2025. PMID: 39997598 Free PMC article.
-
Customized 3D-Printed Scaffolds for Alveolar Ridge Augmentation: A Scoping Review of Workflows, Technology, and Materials.Medicina (Kaunas). 2025 Jul 14;61(7):1269. doi: 10.3390/medicina61071269. Medicina (Kaunas). 2025. PMID: 40731898 Free PMC article. Review.
References
-
- Tallarico M., Park C.-J., Lumbau A.I., Annucci M., Baldoni E., Koshovari A., Meloni S.M. Customized 3D-Printed Titanium Mesh Developed to Regenerate a Complex Bone Defect in the Aesthetic Zone: A Case Report Approached with a Fully Digital Workflow. Materials. 2020;13:3874. doi: 10.3390/ma13173874. - DOI - PMC - PubMed
-
- Scribante A., Ghizzoni M., Pellegrini M., Pulicari F., Manfredini M., Poli P.P., Maiorana C., Spadari F. Full-Digital Customized Meshes in Guided Bone Regeneration Procedures: A Scoping Review. Prosthesis. 2023;5:480–495. doi: 10.3390/prosthesis5020033. - DOI
-
- Lo Giudice R., Galletti C., Tribst J.P.M., Melenchón L.P., Matarese M., Miniello A., Cucinotta F., Salmeri F. In Vivo Analysis of Intraoral Scanner Precision Using Open-Source 3D Software. Prosthesis. 2022;4:554–563. doi: 10.3390/prosthesis4040045. - DOI
-
- D’Ambrosio F., Giordano F., Sangiovanni G., Di Palo M.P., Amato M. Conventional versus Digital Dental Impression Techniques: What Is the Future? An Umbrella Review. Prosthesis. 2023;5:851–875. doi: 10.3390/prosthesis5030060. - DOI
Publication types
LinkOut - more resources
Full Text Sources