LIG-Based High-Sensitivity Multiplexed Sensing System for Simultaneous Monitoring of Metabolites and Electrolytes
- PMID: 39517842
- PMCID: PMC11548767
- DOI: 10.3390/s24216945
LIG-Based High-Sensitivity Multiplexed Sensing System for Simultaneous Monitoring of Metabolites and Electrolytes
Abstract
With improvements in medical environments and the widespread use of smartphones, interest in wearable biosensors for continuous body monitoring is growing. We developed a wearable multiplexed bio-sensing system that non-invasively monitors body fluids and integrates with a smartphone application. The system includes sensors, readout circuits, and a microcontroller unit (MCU) for signal processing and wireless communication. Potentiometric and amperometric measurement methods were used, with calibration capabilities added to ensure accurate readings of analyte concentrations and temperature. Laser-induced graphene (LIG)-based sensors for glucose, lactate, Na+, K+, and temperature were developed for fast, cost-effective production. The LIG electrode's 3D porous structure provided an active surface area 16 times larger than its apparent area, resulting in enhanced sensor performance. The glucose and lactate sensors exhibited high sensitivity (168.15 and 872.08 μAmM-1cm-2, respectively) and low detection limits (0.191 and 0.167 μM, respectively). The Na+ and K+ sensors demonstrated sensitivities of 65.26 and 62.19 mVdec-1, respectively, in a concentration range of 0.01-100 mM. Temperature sensors showed an average rate of resistance change per °C of 0.25%/°C, within a temperature range of 20-40 °C, providing accurate body temperature monitoring.
Keywords: K+ sensor; Na+ sensor; glucose sensor; lactate sensor; laser-induced graphene; wearable biosensor.
Conflict of interest statement
The authors declare no conflict of interest.
Figures






Similar articles
-
Wearable Flexible Perspiration Biosensors Using Laser-Induced Graphene and Polymeric Tape Microfluidics.ACS Appl Mater Interfaces. 2023 Aug 16;15(32):38201-38213. doi: 10.1021/acsami.3c04665. Epub 2023 Aug 1. ACS Appl Mater Interfaces. 2023. PMID: 37526921
-
Wearable multiplexed biosensor system toward continuous monitoring of metabolites.Biosens Bioelectron. 2020 Apr 1;153:112038. doi: 10.1016/j.bios.2020.112038. Epub 2020 Jan 18. Biosens Bioelectron. 2020. PMID: 31989942
-
Miniaturized Wearable Biosensors for Continuous Health Monitoring Fabricated Using the Femtosecond Laser-Induced Graphene Surface and Encapsulated Traces and Electrodes.ACS Sens. 2025 Feb 28;10(2):761-772. doi: 10.1021/acssensors.4c02214. Epub 2025 Jan 22. ACS Sens. 2025. PMID: 39838965
-
Laser-induced graphene (LIG)-driven medical sensors for health monitoring and diseases diagnosis.Mikrochim Acta. 2022 Jan 10;189(2):54. doi: 10.1007/s00604-021-05157-6. Mikrochim Acta. 2022. PMID: 35001163 Free PMC article. Review.
-
Laser-Induced Graphene-Based Sensors in Health Monitoring: Progress, Sensing Mechanisms, and Applications.Small Methods. 2024 Nov;8(11):e2400118. doi: 10.1002/smtd.202400118. Epub 2024 Apr 10. Small Methods. 2024. PMID: 38597770 Free PMC article. Review.
References
-
- Garcês B.P., Santos K.d.O., de Oliveira C.A. Project-Based Learning in Metabolic Biochemistry Teaching. Rev. Ibero-Am. Estud. Em Educ. 2018;13:526–533. doi: 10.21723/riaee.nesp1.v13.2018.11448. - DOI
-
- Xu B., Xu L., Cai H., Jiang L., Luo Y., Gu Y. The Design of an M-Health Monitoring System Based on a Cloud Computing Platform. Enterp. Inf. Syst. 2017;11:17–36. doi: 10.1080/17517575.2015.1053416. - DOI
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources