Application of deep learning techniques for breath-hold, high-precision T2-weighted magnetic resonance imaging of the abdomen
- PMID: 39535616
- DOI: 10.1007/s00261-024-04675-0
Application of deep learning techniques for breath-hold, high-precision T2-weighted magnetic resonance imaging of the abdomen
Abstract
Purpose: To evaluate the feasibility of a high-precision single-shot fast spin-echo (SS-FSE) sequence using the deep learning-based Precise IQ Engine (PIQE) algorithm in comparison with standard SS-FSE for T2-weighted MR imaging of the abdomen, and to compare the image quality with a multi-shot (MS)-FSE sequence using the PIQE algorithm.
Methods: This retrospective study included 105 patients who underwent abdominal MR including T2-weighted sequences using the PIQE reconstruction algorithm. The image quality, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in high-precision SS-FSE sequences using PIQE were compared to those in standard SS-FSE without PIQE and MS-FSE sequences using PIQE.
Results: The scores for all qualitative parameters were significantly higher in high-precision SS-FSE sequence using PIQE than in standard SS-FSE sequence without PIQE (all p < 0.001). In the comparison between two high-precision sequences using PIQE, the SS-FSE sequence showed significantly better scores for the blurring, ghosts or motion/flow artifacts, conspicuity of intrahepatic structures, focal nonsolid hepatic and pancreatic cystic lesions, and overall image quality, in comparison to the MS-FSE sequence (all p < 0.001). Additionally, the SS-FSE sequence using PIQE showed significantly higher SNR of the liver and CNR of nonsolid hepatic lesions than the MS-FSE sequence using PIQE (p < 0.001).
Conclusions: A high-precision SS-FSE sequence using the PIQE algorithm is a feasible alternative to the standard FSE sequence in T2-weighted MR imaging of the abdomen. It can improve image quality, the SNR of the liver, and the ability to visualize nonsolid focal liver lesions and pancreatic cystic lesions in comparison to a high-precision MS-FSE sequence using PIQE although this study was limited by single-center design and lack of pathological confirmation.
Keywords: Abdomen; Breath holding; Deep learning; Image reconstruction; MRI.
© 2024. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.
Similar articles
-
High-precision MRI of liver and hepatic lesions on gadoxetic acid-enhanced hepatobiliary phase using a deep learning technique.Jpn J Radiol. 2025 Apr;43(4):649-655. doi: 10.1007/s11604-024-01693-2. Epub 2024 Nov 11. Jpn J Radiol. 2025. PMID: 39527182 Free PMC article.
-
Clinical feasibility of an abdominal thin-slice breath-hold single-shot fast spin echo sequence processed using a deep learning-based noise-reduction approach.Magn Reson Imaging. 2022 Jul;90:76-83. doi: 10.1016/j.mri.2022.04.005. Epub 2022 Apr 30. Magn Reson Imaging. 2022. PMID: 35504409
-
Utility of breath-hold fast-recovery fast spin-echo t2 versus respiratory-triggered fast spin-echo T2 in clinical hepatic imaging.AJR Am J Roentgenol. 2005 Mar;184(3):842-6. doi: 10.2214/ajr.184.3.01840842. AJR Am J Roentgenol. 2005. PMID: 15728606
-
Ultrafast T2-weighted imaging of the abdomen and pelvis: use of single shot fast spin-echo imaging.J Magn Reson Imaging. 1998 Mar-Apr;8(2):384-90. doi: 10.1002/jmri.1880080218. J Magn Reson Imaging. 1998. PMID: 9562065 Review.
-
Advanced MRI techniques in abdominal imaging.Abdom Radiol (NY). 2024 Oct;49(10):3615-3636. doi: 10.1007/s00261-024-04369-7. Epub 2024 May 28. Abdom Radiol (NY). 2024. PMID: 38802629 Review.
References
-
- Reinig JW (1995) Breath-hold fast spin–echo MR imaging of the liver: a technique for high-quality T2-weighted images. Radiology. 194(2):303–304. https://doi.org/10.1148/radiology.194.2.7824701 - DOI - PubMed
-
- Ito K, Mitchell DG, Outwater EK, Szklaruk J, Sadek AG (1997) Hepatic lesions: discrimination of nonsolid, benign lesions from solid, malignant lesions with heavily T2-weighted fast spin–echo MR imaging. Radiology. 204(3):729–737. https://doi.org/10.1148/radiology.204.3.9280251 - DOI - PubMed
-
- Lee MG, Jeong YK, Kim JC, Kang EM, Kim PN, Auh YH, Chien D, Laub G (2000) Fast T2-weighted liver MR imaging: comparison among breath-hold turbo-spin–echo, HASTE, and inversion recovery (IR) HASTE sequences. Abdom Imaging. 25(1):93–99. https://doi.org/10.1007/s002619910019 - DOI - PubMed
-
- Lee SS, Byun JH, Hong HS, Park SH, Won HJ, Shin YM, Lee MG (2007) Image quality and focal lesion detection on T2-weighted MR imaging of the liver: comparison of two high-resolution free-breathing imaging techniques with two breath-hold imaging techniques. J Magn Reson Imaging. 26(2):323–330. https://doi.org/10.1002/jmri.21002 - DOI - PubMed
-
- Mule S, Kharrat R, Zerbib P, Massire A, Nickel MD, Ambarki K, Reizine E, Baranes L, Zegai B, Pigneur F, Kobeiter H, Luciani A (2022) Fast T2-weighted liver MRI: Image quality and solid focal lesions conspicuity using a deep learning accelerated single breath-hold HASTE fat-suppressed sequence. Diagn Interv Imaging. 103(10):479–485. https://doi.org/10.1016/j.diii.2022.05.001 - DOI - PubMed
MeSH terms
LinkOut - more resources
Full Text Sources
Medical