Conduction system pacing in heart failure: Time for a paradigm shift?
- PMID: 39579301
- DOI: 10.1007/s10741-024-10469-9
Conduction system pacing in heart failure: Time for a paradigm shift?
Abstract
Heart failure (HF) is a major clinical challenge characterized by significant morbidity and mortality. Electrical conduction abnormalities play a critical role in HF pathophysiology and progression, often leading to suboptimal outcomes with conventional pacing techniques. Con-duction system pacing (CSP), encompassing His bundle pacing and left bundle branch area pacing, has emerged as a novel approach. Despite data come from observational studies, recent guidelines recommend that a specific population may benefit from CSP. However, significant practical considerations and challenges need to be clarified before CSP can be routinely implemented in clinical practice. The reliance on observational studies means that long-term clinical outcomes for HF patients remain uncertain until data from randomized controlled trials (RCTs) become available. Current CSP practices face challenges with lead implantation, mechanical stress on leads, and the need for more advanced tools and artificial intelligence integration to improve procedure efficacy and safety. Future large-scale RCTs are essential to identify optimal candidates and address these technical challenges, potentially leading to a paradigm shift in HF management.
Keywords: Cardiac resynchronization; Conduction abnormalities; Conduction system pacing; His-pacing; LBBA-pacing; LBBB; Pacemaker induced-cardiomyopathy.
© 2024. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.
Conflict of interest statement
Declarations. Ethical approval: Ethical approval is not applicable as the current paper is review. Competing interests: The authors declare no competing interests.
References
-
- Savarese G, Lund LH (2017) Global Public Health Burden of Heart Failure. Cardiac Fail Rev 3(1):7–11 - DOI
-
- Benjamin EJ, Virani SS, Callaway CW, Chamberlain AM, Chang AR, Cheng S, Chiuve SE, Cushman M, Delling FN, Deo R, de Ferranti SD, Ferguson JF, Fornage M, Gillespie C, Isasi CR, Jimenez MC, Jordan LC, Judd SE, Lackland D, Lichtman JH, Lisabeth L, Liu S, Longenecker CT, Lutsey PL, Mackey JS, Matchar DB, Matsushita K, Mussolino ME, Nasir K, O’Flaherty M, Palaniappan LP, Pandey A, Pandey DK, Reeves MJ, Ritchey MD, Rodriguez CJ, Roth GA, Rosamond WD, Sampson UKA, Satou GM, Shah SH, Spartano NL, Tirschwell DL, Tsao CW, Voeks JH, Willey JZ, Wilkins JT, Wu JH, Alger HM, Wong SS, Muntner P (2018) Circulation 137(12):e67–e492 American Heart Association Council on, E.; Prevention Statistics, C.; Stroke Statistics, S., Heart Disease and Stroke Statistics-2018 Update: A Report From the American Heart Association - PubMed - DOI
-
- Hussein AA, Wilkoff BL (2019) Cardiac Implantable Electronic device therapy in Heart failure. Circul Res 124(11):1584–1597 - DOI
-
- Abraham WT, Fisher WG, Smith AL, Delurgio DB, Leon AR, Loh E, Kocovic DZ, Packer M, Clavell AL, Hayes DL, Ellestad M, Trupp RJ, Underwood J, Pickering F, Truex C, McAtee P, Messenger J, Evaluation M.S.M.S.G.M.I.R.C (2002) Cardiac resynchronization in chronic heart failure. N Engl J Med 346(24):1845–1853. - PubMed - DOI