High-efficient white blood cell separation from whole blood using cascaded inertial microfluidics
Abstract
White blood cells (WBCs) are a crucial component of the human immune system. WBCs contain invaluable information about the health status of the human body. Therefore, separating WBCs is indispensable for the diagnosis of many diseases in clinical setting. The low ratio of WBCs to red blood cells in whole blood has made the isolation of WBCs challenging. As the conventional single-stage microfluidic technology cannot provide sufficient separation purity. We used a cascaded inertial microfluidic chip by consecutively connecting two sinusoidal channels to enhance the purity of WBCs after single processing. The improvement was in part due to the diversion of the sample at the end of the first stage separation, resulting in a lower flow rate in the second stage of processing within the cascaded device. We embedded concave micro-obstacles in sinusoidal channels to adjust their effective working flow rate range and enable the proper operation of both channels simultaneously. Using polystyrene beads mixture (5 and 10 μm) with a primary ratio of 1000 to 1, a single processing step through our cascaded chip improved the purity of 10-μm particles with more than three orders of magnitude of enrichment (from 0.08 % to 99.83 %) with a flow rate of 560 μL/min (Re = 77). Using diluted whole blood ( × 1/10), we achieved 307-fold enrichment of WBCs (0.14 %-43.017 %) in a single process which was accompanied with ∼3 orders of magnitude background removal of RBCs (from 4.8 × 108 to 5.7 × 105 counts/mL). This cascaded manner chip has the capacity to achieve high-efficiency separation of blood cells for clinical diagnosis.
Copyright © 2024 The Authors. Published by Elsevier B.V. All rights reserved.
Conflict of interest statement
Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Similar articles
-
High-Throughput Separation of White Blood Cells From Whole Blood Using Inertial Microfluidics.IEEE Trans Biomed Circuits Syst. 2017 Dec;11(6):1422-1430. doi: 10.1109/TBCAS.2017.2735440. Epub 2017 Aug 29. IEEE Trans Biomed Circuits Syst. 2017. PMID: 28866599
-
Robust and efficient separation of white blood cells from blood using a microfluidic chip with a pair of linearly tapered crossflow filter arrays.Mikrochim Acta. 2024 Dec 30;192(1):41. doi: 10.1007/s00604-024-06913-0. Mikrochim Acta. 2024. PMID: 39738679
-
Micropump integrated white blood cell separation platform for detection of chronic granulomatous disease.Mikrochim Acta. 2024 May 3;191(5):295. doi: 10.1007/s00604-024-06372-7. Mikrochim Acta. 2024. PMID: 38700804
-
Microfluidic Systems for Isolation of White Blood Cells: From Design to Practical Applications.Crit Rev Anal Chem. 2025 Jun 12:1-25. doi: 10.1080/10408347.2025.2514795. Online ahead of print. Crit Rev Anal Chem. 2025. PMID: 40504678 Review.
-
Microfluidic Devices for Circulating Tumor Cells Isolation and Subsequent Analysis.Curr Pharm Biotechnol. 2016;17(9):810-21. doi: 10.2174/1389201017666160301103509. Curr Pharm Biotechnol. 2016. PMID: 26927214 Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials