Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2025 Mar 1:284:127200.
doi: 10.1016/j.talanta.2024.127200. Epub 2024 Nov 14.

High-efficient white blood cell separation from whole blood using cascaded inertial microfluidics

Affiliations
Free article

High-efficient white blood cell separation from whole blood using cascaded inertial microfluidics

Haotian Cha et al. Talanta. .
Free article

Abstract

White blood cells (WBCs) are a crucial component of the human immune system. WBCs contain invaluable information about the health status of the human body. Therefore, separating WBCs is indispensable for the diagnosis of many diseases in clinical setting. The low ratio of WBCs to red blood cells in whole blood has made the isolation of WBCs challenging. As the conventional single-stage microfluidic technology cannot provide sufficient separation purity. We used a cascaded inertial microfluidic chip by consecutively connecting two sinusoidal channels to enhance the purity of WBCs after single processing. The improvement was in part due to the diversion of the sample at the end of the first stage separation, resulting in a lower flow rate in the second stage of processing within the cascaded device. We embedded concave micro-obstacles in sinusoidal channels to adjust their effective working flow rate range and enable the proper operation of both channels simultaneously. Using polystyrene beads mixture (5 and 10 μm) with a primary ratio of 1000 to 1, a single processing step through our cascaded chip improved the purity of 10-μm particles with more than three orders of magnitude of enrichment (from 0.08 % to 99.83 %) with a flow rate of 560 μL/min (Re = 77). Using diluted whole blood ( × 1/10), we achieved 307-fold enrichment of WBCs (0.14 %-43.017 %) in a single process which was accompanied with ∼3 orders of magnitude background removal of RBCs (from 4.8 × 108 to 5.7 × 105 counts/mL). This cascaded manner chip has the capacity to achieve high-efficiency separation of blood cells for clinical diagnosis.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Similar articles

MeSH terms

LinkOut - more resources