Assessment of vibration induced white finger: reliability and validity of two tests
- PMID: 3964578
- PMCID: PMC1007649
- DOI: 10.1136/oem.43.4.284
Assessment of vibration induced white finger: reliability and validity of two tests
Abstract
The reliability and validity of two tests (cold water and reactive hyperaemia) designed to confirm a patient's history of vibration induced white finger were studied. The cold water test is a measure of digital rewarming after hand immersion in cold water. Reactive hyperaemia consists of measuring digital rewarming after cold water immersion plus temporary ischaemia imposed on the hand. For ten weeks, ten healthy male volunteers were submitted once a week to both tests to study their reliability. The results showed a strong inter and intraindividual scattering. The mean value for the whole group, however, did not differ significantly from one week to the next. Fifty two subjects exposed to hand/arm vibration were submitted to both tests to estimate their validity. They were classified, according to their medical history, into three groups: A = no symptoms, B = tingling or numbess, or both, C = Raynaud's phenomenon. Both tests agreed with the clinical staging. For reactive hyperaemia, however, the differences between the groups were statistically significant only when the test was performed at 10 degrees C. These tests are more useful to study a group than an individual case. Time has no significant effect on the mean result of a group.
Similar articles
-
Infrared thermography in the diagnosis of Raynaud's phenomenon in vibration-induced white finger.Vasa. 1998 May;27(2):94-9. Vasa. 1998. PMID: 9612113
-
Finger systolic blood pressure indices for the diagnosis of vibration-induced white finger.Int Arch Occup Environ Health. 2002 Jan;75(1-2):20-8. doi: 10.1007/s004200100274. Int Arch Occup Environ Health. 2002. PMID: 11898873
-
Diagnostic aspects of vibration-induced white finger.Int Arch Occup Environ Health. 2002 Jan;75(1-2):6-13. doi: 10.1007/s004200100272. Int Arch Occup Environ Health. 2002. PMID: 11898878 Review.
-
Finger blood pressure and rewarming rate for screening and diagnosis of Raynaud's phenomenon in workers exposed to vibration.Br J Ind Med. 1991 Jul;48(7):480-4. doi: 10.1136/oem.48.7.480. Br J Ind Med. 1991. PMID: 1854650 Free PMC article.
-
Finger thermometry in the assessment of subjects with vibration-induced white finger.Scand J Work Environ Health. 1987 Aug;13(4):348-51. doi: 10.5271/sjweh.2044. Scand J Work Environ Health. 1987. PMID: 3324314 Review.
Cited by
-
Diagnosis of vascular injuries caused by hand-transmitted vibration.Int Arch Occup Environ Health. 2008 Apr;81(5):507-18. doi: 10.1007/s00420-007-0246-4. Epub 2007 Sep 26. Int Arch Occup Environ Health. 2008. PMID: 17899161 Review.
-
Assessment of two alternative standardised tests for the vascular component of the hand-arm vibration syndrome (HAVS).Occup Environ Med. 2016 Oct;73(10):701-8. doi: 10.1136/oemed-2016-103688. Epub 2016 Aug 17. Occup Environ Med. 2016. PMID: 27535036 Free PMC article.
-
Test battery for assessing vascular disturbances of fingers.Environ Health Prev Med. 2005 Nov;10(6):341-50. doi: 10.1007/BF02898195. Environ Health Prev Med. 2005. PMID: 21432118 Free PMC article.
-
Different conditions of cold water immersion test for diagnosing hand-arm vibration syndrome.Environ Health Prev Med. 2005 Nov;10(6):351-9. doi: 10.1007/BF02898196. Environ Health Prev Med. 2005. PMID: 21432119 Free PMC article.
-
Effect of room temperature on tests for diagnosing vibration-induced white finger: finger rewarming times and finger systolic blood pressures.Int Arch Occup Environ Health. 2017 Aug;90(6):527-538. doi: 10.1007/s00420-017-1214-2. Epub 2017 Mar 28. Int Arch Occup Environ Health. 2017. PMID: 28353018 Free PMC article.
References
MeSH terms
LinkOut - more resources
Full Text Sources
Medical