. 2025 Apr;63(4):1189-1200.
doi: 10.1007/s11517-024-03257-y. Epub 2024 Dec 16.

The influence of PEEK acetabular shell on the mechanical stability of total hip replacements under gait loading and motion

Affiliations

The influence of PEEK acetabular shell on the mechanical stability of total hip replacements under gait loading and motion

Hongxing Shi et al. Med Biol Eng Comput. 2025 Apr.

Abstract

The demand for total hip replacement surgery is increasing year by year. However, the issue of hip prosthesis failure, particularly the modular acetabular cup, still exists. The performance and functional requirements of modular acetabular cups have not yet met clinical expectations. This study focused on poly-ether-ether-ketone (PEEK) shells, using finite element methods to investigate their mechanical stability under gait loads and motion, including parameters such as deformation, micromotion, and bone strain. The results showed that a compromise was required among the mechanical performance, stability, and bone integration capabilities of the PEEK shell. As the shell rigidity increased, deformation decreased. However, increased rigidity also increased micromotion at the bone-prosthesis interface, reducing the area that promoted bone ingrowth. Additionally, potential bone absorption areas were also increased, reducing bone preservation and reconstruction capabilities. Compromises need to be made among mechanical performance, stability, and bone integration to achieve optimal mechanical stability. In this study, a 6 mm wall thickness PEEK shell was found to provide good overall mechanical stability.

Keywords: Gait load; Implant deformation; Micromotion; Poly-ether-ether-ketone (PEEK); Strain; Total hip replacement.

PubMed Disclaimer

Conflict of interest statement

Declarations. Conflict of interest: The authors declare no competing interests.

References

    1. Cui W, Zhang Y, Wang Z et al (2019) Review of the artificial hip and knee wear testing standards and simulation testing machines. Tribology 39(2):248–258
    1. Bernasek TL, Gill M, Herekar R et al (2023) Total joint replacement, contemporary concepts. In: Harrison EE, Ho NH (eds) Managing cardiovascular risk in elective total joint arthroplasty. Springer International Publishing, Cham, pp 7–22 (ISBN 978-3-031-26414-6)
    1. Bian YY, Cheng KY, Chang X et al (2020) Reports and analysis of amount of hip and knee arthroplasty in China from 2011 to 2019. Chin J Orthop 40(21):1453–1460
    1. Kalayarasan M, Dhanabal P, Shankar S et al (2024) Unveiling the influence of one-leg stance and standing up from a chair on human hip joint prosthesis using finite element concepts. J Mech Med Biol. https://doi.org/10.1142/S0219519424500192
    1. Jasty M, Maloney W, Bragdon C et al (1991) The Initiation of failure in cemented femoral components of hip arthroplasties. J Bone Joint Surg 73(4):551–558