Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2025 Feb;14(2):323-335.
doi: 10.1007/s40123-024-01080-0. Epub 2024 Dec 16.

Long-Term Treatment Outcomes of Micropulse Transscleral Cyclophotocoagulation in Primary and Secondary Glaucoma: A 5-Year Analysis

Affiliations

Long-Term Treatment Outcomes of Micropulse Transscleral Cyclophotocoagulation in Primary and Secondary Glaucoma: A 5-Year Analysis

Ronald M P C de Crom et al. Ophthalmol Ther. 2025 Feb.

Abstract

Introduction: To investigate 5-year outcomes on intraocular pressure (IOP) and safety of micropulse transscleral cyclophotocoagulation (TSCPC) in patients with glaucoma.

Methods: Patients with mild to advanced glaucoma who underwent a standardized micropulse TSCPC procedure at the University Eye Clinic Maastricht from November 2016 to February 2019 were included.

Results: A total of 165 eyes were included, with outcomes for 112 eyes available after 5-year follow-up. Mean age was 67.3 ± 13.9 years; 58.2% were male. Glaucoma subtypes were primary glaucoma (n = 108) and secondary glaucoma (n = 57). Prior glaucoma surgery was performed in 65 of 165 eyes (39.4%). In the primary glaucoma group, mean preoperative IOP was 20.7 ± 7.1 mmHg. Mean postoperative IOP at 1, 2, 3, 4, and 5 years significantly reduced to 15.2 ± 6.5, 14.3 ± 5.0, 14.0 ± 4.9, 13.5 ± 4.1, and 12.9 ± 4.3 mmHg, respectively. Preoperatively, the mean number of IOP-lowering medications was 3.3 ± 1.3, which changed to 2.8 ± 1.3, 2.8 ± 1.2, 2.8 ± 1.2, 2.9 ± 1.2, and 2.7 ± 1.3 at 1, 2, 3, 4, and 5 years, respectively. In the secondary glaucoma group, mean preoperative IOP was 28.7 ± 10.3 mmHg, dropping significantly to 19.3 ± 10.4, 18.6 ± 11.3, 17.8 ± 9.8, 18.1 ± 12.0, and 15.5 ± 7.6 mmHg at the same intervals. The number of IOP-lowering medication was significantly reduced from 3.5 ± 1.1 to 2.5 ± 1.5, 2.2 ± 1.5, 2.6 ± 1.4, 2.6 ± 1.5, and 2.5 ± 1.7. In the total group, mean IOP reduction was 32.5% after 5 years. Postoperative complications included cystic macular edema (n = 3), fibrinous/uveitic reaction (n = 1), and rejection of corneal graft (n = 2), all reversible after treatment. One patient developed late and persisting hypotony. Other adverse events were retinal venous occlusion (n = 1) and retinal vasculitis (n = 1), unrelated to the laser treatment. In patients with a preoperative Central Distance Visual Acuity (CDVA) > 0.05 on the Snellen chart, more than two lines of visual acuity (VA) loss were attributed to cataract (n = 10), retinal disease (n = 5), glaucoma progression (n = 3), corneal decompensation (n = 2), or other factors (n = 11).

Conclusion: Micropulse TSCPC is a safe and effective treatment for reducing IOP and the number of IOP-lowering medications after a 5-year follow-up period. It is a viable alternative for patients after failed incisional glaucoma surgery or high-risk patients.

Keywords: Glaucoma; Laser treatment; Micropulse; Transscleral cyclophotocoagulation.

PubMed Disclaimer

Conflict of interest statement

Declarations. Conflict of Interest: Ronald M.P.C. de Crom has received speaker honorarium from IRIDEX Corporation. Stefani Kujovic-Aleksov, Carroll A.B. Webers, Tos T.J.M. Berendschot, and Henny J.M. Beckers declare that they have no competing interests. Ethical Approval: This study was conducted according to guidelines of the Declaration of Helsinki and its later amendments or comparable ethical standards and was approved by the institutional ethics committee (METC) operating at the Maastricht University Medical Centre + in Maastricht, The Netherlands, No METC 2020-2404 (24-12-2020). All patients gave informed consent prior to undergoing treatment.

Figures

Fig. 1
Fig. 1
IOP and number of glaucoma medications in total patient cohort. Intraocular pressure (IOP) in mean mmHg, number of medications in mean, *significant p < 0.001 compared with preoperative values, **significant p < 0.005 compared with preoperative values, Significant p < 0.01 compared with preoperative values, ₸₸Significant p < 0.05 compared with preoperative values

Similar articles

Cited by

References

    1. Weinreb RN, Khaw PT. Primary open-angle glaucoma. Lancet. 2004;363(9422):1711–20. - PubMed
    1. Weinreb RN, Aung T, Medeiros FA. The pathophysiology and treatment of glaucoma: a review. JAMA. 2014;311(18):1901–11. - PMC - PubMed
    1. Chen MF, Kim CH, Coleman AL. Cyclodestructive procedures for refractory glaucoma. Cochrane Database Syst Rev. 2019;3:CD012223. - PMC - PubMed
    1. Dastiridou AI, Katsanos A, Denis P, Francis BA, Mikropoulos DG, Teus MA, Konstas AG. Cyclodestructive procedures in glaucoma: a review of current and emerging options. Adv Ther. 2018;35(12):2103–27. - PMC - PubMed
    1. Kosoko O, Gaasterland DE, Pollack IP, Enger CL. Long-term outcome of initial ciliary ablation with contact diode laser transscleral cyclophotocoagulation for severe glaucoma. The diode laser ciliary ablation study group. Ophthalmology. 1996;103(8):1294–302. - PubMed

LinkOut - more resources